| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 336 / 336 |
| EER2 · BTU/Wh | 9.5–10.5 | 336 / 336 |
| HSPF2 · BTU/Wh | 8.1–9 | 336 / 336 |
| Cooling capacity · BTU/h | 28,600–31,200 | 336 / 336 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 336 / 336 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 336 / 336 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 336 / 336 |
| COP at 5°F / −15°C | 1.75–2 | 336 / 336 |
| Equipment / loop type | HP - Split System | 336 / 336 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 336 / 336 |
| Compressor staging | Continuously variable | 336 / 336 |
| Connected capability | No | 336 / 336 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X43M21A*+ furnace: *96VSN0401712B*Cold climate designationAHRI reference: 218490210 | 15.50 | 9.00 | 32400 | 1.96 | EPA 4634633 → |
EA*5X43M21A*+ furnace: *96MSN1002122A*Cold climate designationAHRI reference: 218490203 | 15.50 | 9.00 | 32200 | 1.98 | EPA 4634640 → |
EA*5X43M21A*+ furnace: *96MSN0802120A*Cold climate designationAHRI reference: 218490189 | 15.50 | 9.00 | 32200 | 1.96 | EPA 4634654 → |
EA*5X43M21A*+ furnace: *96MSN0801716A*Cold climate designationAHRI reference: 218490181 | 15.50 | 9.00 | 32200 | 1.98 | EPA 4634662 → |
EA*5X30M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218491934 | 15.50 | 8.50 | 33400 | 1.78 | EPA 4635581 → |
EA*5X36M17A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218491653 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635637 → |
EA*5X36M17A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218491646 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635644 → |
EA*5X36M17A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218491639 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635651 → |
EA*5X36M17A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218491632 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635658 → |
EA*5X36M17A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218491597 | 15.50 | 8.50 | 33400 | 1.76 | EPA 4635679 → |
EA*5X36M17A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218491590 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635686 → |
EA*5X36M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218491583 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635693 → |
EA*5X36M17A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 218491526 | 15.50 | 8.50 | 33200 | 1.76 | EPA 4635707 → |
EA*5X36M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 218491498 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635735 → |
EA*5X36M17A*+ furnace: *80VSL0451412B*Cold climate designationAHRI reference: 218491456 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635777 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0901714A*Cold climate designationAHRI reference: 218491449 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635784 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0701712A*Cold climate designationAHRI reference: 218491435 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635798 → |
EA*5X36M17A*+ furnace: *80MS(N,L)0701412A*Cold climate designationAHRI reference: 218491428 | 15.50 | 8.50 | 33200 | 1.78 | EPA 4635805 → |
EA*5X37M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218491407 | 15.50 | 9.00 | 32600 | 1.98 | EPA 4635819 → |
EA*5X37M17A*+ furnace: *96VTN0601412B*Cold climate designationAHRI reference: 218491358 | 15.50 | 9.00 | 32600 | 1.94 | EPA 4635854 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →