Day & Night / AIR-SOURCE HEAT PUMP

C5H8T60*K*AAA*

Mainline 18 SEER2 HP · source records, page 3

85 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.585 / 85
EER2 · BTU/Wh11.7–1385 / 85
HSPF2 · BTU/Wh7.8–8.585 / 85
Cooling capacity · BTU/h54,000–58,00085 / 85
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50085 / 85
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50085 / 85
Heating capacity at 5°F / −15°C · BTU/h29,600–31,80085 / 85
COP at 5°F / −15°C2.18–2.3685 / 85
Equipment / loop typeHP - Split System85 / 85
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)85 / 85
Compressor stagingTwo-stage85 / 85
Connected capabilityNo85 / 85

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *80VSL1102122B*AHRI reference: 21634694616.008.10304002.24EPA 3805336 →
EVD5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21634696216.008.10304002.26EPA 3805352 →
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21634623416.008.10302002.24EPA 3805524 →
EVM5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634627416.008.10300002.26EPA 3805533 →
EVD5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21634775416.008.50316002.34EPA 3805652 →
EA*5X61M21A*+ furnace: *96VSN0802120B*AHRI reference: 21634849816.007.80304002.20EPA 3805724 →
EA*5X61M21A*+ furnace: *96VSN1002120B*AHRI reference: 21634850616.007.80302002.20EPA 3805732 →
EA*5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21634852216.007.80302002.20EPA 3805740 →
EA*5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21634853016.007.80302002.22EPA 3805748 →
EVD5X60M21A*+ furnace: *80VTL1102122B*AHRI reference: 21634701016.008.10304002.24EPA 3805855 →
EA*5X61M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634867416.007.80300002.20EPA 3806014 →
EVD5X60M21A*+ furnace: *96VTN1002122B*AHRI reference: 21634713016.008.10302002.24EPA 3806078 →
EA*5X60M24A*+ furnace: *80VTL0902120B*AHRI reference: 21634810616.007.80298002.22EPA 3806748 →
EA*5X60M24A*+ furnace: *80VTL1102122B*AHRI reference: 21634811416.007.80298002.22EPA 3806756 →
EA*5X61M24A*+ furnace: *96VSN0802120B*AHRI reference: 21634881016.007.80302002.22EPA 3806767 →
EA*5X61M24A*+ furnace: *96VSN1002120B*AHRI reference: 21634881816.007.80302002.22EPA 3806775 →
EA*5X61M24A*+ furnace: *96VSN1202422B*AHRI reference: 21634882616.007.80300002.20EPA 3806784 →
EA*5X61M24A*+ furnace: *95MSU0802120A*AHRI reference: 21634883416.007.80302002.22EPA 3806792 →
EA*5X61M24A*+ furnace: *95MSU1002120A*AHRI reference: 21634884216.007.80302002.20EPA 3806799 →
EA*5X60M24A*+ furnace: *80VSL0902120B*AHRI reference: 21634803416.007.80298002.22EPA 3806822 →