Day & Night / AIR-SOURCE HEAT PUMP

C5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 25

498 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X30M12A*+ furnace: *96VSN0601412B*AHRI reference: 21636786316.007.80112002.00EPA 3812866 →
ESH5X24M12A*+ furnace: *96VTN0601412B*AHRI reference: 21636734815.507.80111002.00EPA 3809719 →
EA*5X24M14A*+WALLCON+ furnace: *96CTN0401410B*AHRI reference: 21636453915.508.00114001.98EPA 3809730 →
EA*5X24M14A*+ furnace: *96VTN0401410B*AHRI reference: 21636454715.508.10112002.04EPA 3809739 →
ESH5X30M12A*+ furnace: OLV098A12*AHRI reference: 21636811015.507.80115001.98EPA 3809846 →
EA*5X24M17A*+ furnace: *96VSN0401410B*AHRI reference: 21636469915.507.80114001.96EPA 3810347 →
EA*5X30M17A*+ furnace: *96VTN0401410B*AHRI reference: 21636550715.507.80112001.96EPA 3811119 →
ESH5X24M12A*+ furnace: *96VSN0601412B*AHRI reference: 21636719615.507.80111002.00EPA 3811593 →
EA*5X25M17A*+TDRAHRI reference: 21636441915.507.80111002.02EPA 3811619 →
EA*5X37M21A*+TDRAHRI reference: 21636445915.507.80111002.02EPA 3811627 →
ESH5X30M12A*+ furnace: *97VTN0601716A*AHRI reference: 21636820615.507.80111002.00EPA 3811771 →
ESH5X30M12A*+ furnace: *97VTN0801716A*AHRI reference: 21636821415.507.80111002.02EPA 3811779 →
ESH5X30M12A*+ furnace: *97VTN0802120A*AHRI reference: 21636822215.507.80111002.02EPA 3811933 →
ESH5X30M12A*+ furnace: *97VTN1002120A*AHRI reference: 21636823015.507.80110002.02EPA 3812090 →
ESH5X30M12A*+ furnace: *96VTN0401712B*AHRI reference: 21636804615.507.80113002.00EPA 3812114 →
EA*5X24M17A*+ furnace: *96VTN0401410B*AHRI reference: 21636477915.507.80113001.94EPA 3812571 →
ESH5X30M12A*+ furnace: *96VSN0401712B*AHRI reference: 21636785215.507.80113002.00EPA 3812858 →
ESH5X24M12A*+ furnace: *96VSN0401410B*AHRI reference: 21636718015.207.80112001.98EPA 3811585 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →