SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X30M14A*+ furnace: *96VSN0401410B*AHRI reference: 21636525116.007.80111001.98EPA 3809188 →
EA*5X30M14A*+WALLCON+ furnace: *96CTN0401410B*AHRI reference: 21636526716.008.00113002.00EPA 3809204 →
ESH5X30M12A*+ furnace: OMV112K14AAHRI reference: 21636812616.008.00114002.02EPA 3809286 →
ESH5X30M12A*+WALLCON+ furnace: *80CSU1002120B*AHRI reference: 21636815816.008.00112002.06EPA 3809406 →
ESH5X30M12A*+WALLCON+ furnace: *97CTN0601716A*AHRI reference: 21636816616.008.00113002.06EPA 3809414 →
EA*5X36M17A*+ furnace: *96VSN0401410B*AHRI reference: 21636575816.007.80112001.98EPA 3809479 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21636729216.007.80113001.98EPA 3809575 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN0801714B*AHRI reference: 21636730016.007.80112002.00EPA 3809586 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN0802120B*AHRI reference: 21636730816.007.80112002.00EPA 3809597 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN1002122B*AHRI reference: 21636731616.008.00112002.06EPA 3809609 →
ESH5X24M12A*+WALLCON+ furnace: *96CTN1202422B*AHRI reference: 21636732416.007.80112002.00EPA 3809617 →
ESH5X30M12A*+ furnace: *96VTN0601412B*AHRI reference: 21636805416.007.80112002.00EPA 3809790 →
ESH5X30M12A*+ furnace: *96VTN0601716B*AHRI reference: 21636806216.007.80111002.00EPA 3809797 →
ESH5X30M12A*+ furnace: *96VTN0801716B*AHRI reference: 21636807016.007.80111002.02EPA 3809805 →
ESH5X24M12A*+WALLCON+ furnace: *80CSU0401712A*AHRI reference: 21636690016.007.80112002.00EPA 3810030 →
ESH5X24M12A*+WALLCON+ furnace: *80CSU0601716A*AHRI reference: 21636690816.007.80112002.00EPA 3810038 →
ESH5X24M12A*+ furnace: *80VSL0451412B*AHRI reference: 21636692416.007.80110002.02EPA 3810047 →
ESH5X24M12A*+ furnace: *80VTL0701716B*AHRI reference: 21636708416.007.80111002.00EPA 3810054 →
ESH5X24M12A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21636705216.007.80112002.00EPA 3810074 →
ESH5X30M12A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21636799816.008.00112002.04EPA 3810181 →