Day & Night / AIR-SOURCE HEAT PUMP

C5H8T24*K*AAA*

Mainline 18 SEER2 HP · source records, page 2

498 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for C5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5498 / 498
EER2 · BTU/Wh11.7–14498 / 498
HSPF2 · BTU/Wh7.8–8.5498 / 498
Cooling capacity · BTU/h22,200–25,000498 / 498
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400498 / 498
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000498 / 498
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500498 / 498
COP at 5°F / −15°C1.94–2.24498 / 498
Equipment / loop typeHP - Split System498 / 498
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)498 / 498
Compressor stagingTwo-stage498 / 498
Connected capabilityNo498 / 498

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 21636680418.008.10112002.12EPA 3809686
EA*5X37M21A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 21636681218.008.50112002.24EPA 3809692
EA*5X37M21A*+ furnace: *97VTN0802120A*AHRI reference: 21636687618.008.50112002.22EPA 3810006
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 21636689218.008.50112002.22EPA 3810022
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21636493918.008.10111002.12EPA 3810232
EA*5X25M17A*+ furnace: *80VSL0701412B*AHRI reference: 21636491518.008.10110002.12EPA 3810374
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 21636492318.008.10111002.12EPA 3810422
EA*5X25M17A*+WALLCON+ furnace: *80CSU0401712A*AHRI reference: 21636489118.008.10112002.12EPA 3810432
EA*5X37M21A*+WALLCON+ furnace: *97CTN1002122A*AHRI reference: 21636685218.008.10112002.12EPA 3810761
EA*5X37M21A*+WALLCON+ furnace: *80CTL0901716B*AHRI reference: 21636650018.008.10112002.12EPA 3810881
EA*5X37M21A*+WALLCON+ furnace: *80CTL0902120B*AHRI reference: 21636650818.008.10112002.12EPA 3810889
EA*5X37M21A*+WALLCON+ furnace: *80CTL1102120B*AHRI reference: 21636651618.008.10112002.12EPA 3810896
EA*5X37M21A*+WALLCON+ furnace: *80CSU0601716A*AHRI reference: 21636639618.008.10112002.12EPA 3810987
EA*5X37M21A*+ furnace: *80VSL0901716B*AHRI reference: 21636642018.008.10111002.12EPA 3811011
EA*5X37M21A*+ furnace: *80VSL1102122B*AHRI reference: 21636643618.008.50111002.22EPA 3811027
EA*5X37M21A*+ furnace: *80MSU0401712A*AHRI reference: 21636644418.008.50111002.24EPA 3811035
EA*5X37M21A*+ furnace: *80MSU0601716A*AHRI reference: 21636645218.008.50112002.24EPA 3811043
EVD5X38M17A*+ furnace: *96VSN0601716B*AHRI reference: 21636428318.007.80111002.04EPA 3811246
EVD5X38M17A*+ furnace: *96VTN0601716B*AHRI reference: 21636433918.007.80111002.04EPA 3811450
EVD5X38M17A*+ furnace: OMV112K14AAHRI reference: 21636436318.007.80112002.02EPA 3811458