C5H8T24*K*AAA*
Mainline 18 SEER2 HP · source records, page 11
498 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 498 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18.5 | 498 / 498 |
| EER2 · BTU/Wh | 11.7–14 | 498 / 498 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 498 / 498 |
| Cooling capacity · BTU/h | 22,200–25,000 | 498 / 498 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 24,000–25,400 | 498 / 498 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,100–15,000 | 498 / 498 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,700–11,500 | 498 / 498 |
| COP at 5°F / −15°C | 1.94–2.24 | 498 / 498 |
| Equipment / loop type | HP - Split System | 498 / 498 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 498 / 498 |
| Compressor staging | Two-stage | 498 / 498 |
| Connected capability | No | 498 / 498 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X30M17A*+ furnace: *96VTN0801716B*AHRI reference: 216365539 | 17.00 | 8.10 | 11000 | 2.08 | EPA 3811370 → |
EA*5X30M17A*+ furnace: OMV112K14AAHRI reference: 216365563 | 17.00 | 8.10 | 11200 | 2.04 | EPA 3811394 → |
EA*5X30M17A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 216365571 | 17.00 | 8.00 | 10900 | 2.06 | EPA 3811402 → |
EA*5X36M17A*+ furnace: *80VSL0901716B*AHRI reference: 216365659 | 17.00 | 8.10 | 10900 | 2.10 | EPA 3811520 → |
EA*5X36M17A*+WALLCON+ furnace: *80CTL0451712B*AHRI reference: 216365683 | 17.00 | 8.00 | 11100 | 2.04 | EPA 3811544 → |
EA*5X36M17A*+WALLCON+ furnace: *80CTL0701412B*AHRI reference: 216365691 | 17.00 | 8.00 | 11000 | 2.06 | EPA 3811553 → |
EA*5X36M17A*+WALLCON+ furnace: *80CTL0701716B*AHRI reference: 216365699 | 17.00 | 8.00 | 11000 | 2.06 | EPA 3811560 → |
EA*5X25M17A*+ furnace: *96VSN0601412B*AHRI reference: 216365043 | 17.00 | 8.10 | 11200 | 2.10 | EPA 3811671 → |
EA*5X30M14A*+WALLCON+ furnace: *80CTL0701412B*AHRI reference: 216365235 | 17.00 | 8.00 | 11000 | 2.06 | EPA 3811685 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0401712B*AHRI reference: 216368782 | 17.00 | 8.00 | 11000 | 2.08 | EPA 3811784 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0601716B*AHRI reference: 216368790 | 17.00 | 8.00 | 11100 | 2.08 | EPA 3811806 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0802120B*AHRI reference: 216368798 | 17.00 | 8.00 | 11000 | 2.08 | EPA 3811817 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0401712A*AHRI reference: 216368254 | 17.00 | 8.00 | 11100 | 2.08 | EPA 3811984 → |
EA*5X24M14A*+WALLCON+ furnace: *80CTL0701412B*AHRI reference: 216364507 | 17.00 | 8.00 | 11000 | 2.04 | EPA 3812003 → |
ESH5X36M12A*+WALLCON+ furnace: *80CSU0601716A*AHRI reference: 216368262 | 17.00 | 8.00 | 11100 | 2.06 | EPA 3812037 → |
EA*5X36M17A*+ furnace: *96VTN0801716B*AHRI reference: 216365895 | 17.00 | 8.10 | 10900 | 2.08 | EPA 3812234 → |
EA*5X36M17A*+ furnace: OMV112K14AAHRI reference: 216365925 | 17.00 | 7.80 | 11200 | 1.98 | EPA 3812258 → |
EA*5X25M17A*+WALLCON+ furnace: *97CTN0601716A*AHRI reference: 216365187 | 17.00 | 8.00 | 11300 | 2.06 | EPA 3812310 → |
EA*5X36M17A*+ furnace: *96VTN0601716B*AHRI reference: 216365885 | 17.00 | 8.10 | 11000 | 2.08 | EPA 3812363 → |
EA*5X36M17A*+WALLCON+ furnace: *97CTN0801716A*AHRI reference: 216365964 | 17.00 | 8.00 | 11000 | 2.06 | EPA 3812426 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.