Day & Night / AIR-SOURCE HEAT PUMP

C5H6S24*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 5

193 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for C5H6S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 193 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5193 / 193
EER2 · BTU/Wh11.7–13193 / 193
HSPF2 · BTU/Wh7.8–8.5193 / 193
Cooling capacity · BTU/h22,200–24,400193 / 193
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000193 / 193
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200193 / 193
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900193 / 193
COP at 5°F / −15°C1.98–2.26193 / 193
Equipment / loop typeHP - Split System193 / 193
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)193 / 193
Compressor stagingSingle stage193 / 193
Connected capabilityNo193 / 193

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X38M17A*+ furnace: *96VTN0801716B*AHRI reference: 21416016115.507.80113001.98EPA 3403110 →
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21415760515.507.80114002.10EPA 3403129 →
EA*5X25M17A*+ furnace: *96CTN0801714B*AHRI reference: 21415761315.507.80113002.10EPA 3403137 →
EVM5X32M17A*+ furnace: *96VSN0601716B*AHRI reference: 21415930915.507.80114001.98EPA 3403176 →
EA*5X37M17A*+ furnace: *80MSU0601716A*AHRI reference: 21416097715.507.80112002.10EPA 3403219 →
EVM5X32M17A*+ furnace: *96VSN0801716B*AHRI reference: 21415931715.507.80113001.98EPA 3403288 →
EVM5X32M17A*+ furnace: *96VTN0601716B*AHRI reference: 21415934115.507.80114001.98EPA 3403297 →
EVM5X32M17A*+ furnace: *96VTN0801716B*AHRI reference: 21415934915.507.80113001.98EPA 3403306 →
EA*5X37M21A*+ furnace: *80VSL0902120B*AHRI reference: 21415849315.507.80116002.14EPA 3403347 →
EVD5X31M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21415938915.507.80113001.98EPA 3403354 →
EA*5X37M21A*+ furnace: *80MSU1002120A*AHRI reference: 21415850115.507.80116002.14EPA 3403371 →
EA*5X37M21A*+ furnace: *80VTL0902120B*AHRI reference: 21415858915.507.80116002.14EPA 3403393 →
EA*5X37M21A*+ furnace: *95CSU0601716B*AHRI reference: 21415861315.507.80116002.14EPA 3403403 →
EA*5X37M21A*+ furnace: *95CSU0802120B*AHRI reference: 21415862115.507.80116002.14EPA 3403408 →
EA*5X37M21A*+ furnace: *80CTL0701716B*AHRI reference: 21415854115.507.80115002.14EPA 3403440 →
EA*5X37M21A*+ furnace: *80CTL0702120B*AHRI reference: 21415854915.507.80116002.14EPA 3403449 →
EA*5X37M21A*+ furnace: *80CTL0901716B*AHRI reference: 21415855715.507.80115002.14EPA 3403456 →
EA*5X37M21A*+ furnace: *80CTL1102120B*AHRI reference: 21415856515.507.80116002.14EPA 3403463 →
EA*5X37M21A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21416104915.507.80114002.14EPA 3403473 →
EA*5X37M21A*+ furnace: *80MS(N,L)0902120A*AHRI reference: 21416106515.507.80116002.14EPA 3403479 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →