Day & Night / AIR-SOURCE HEAT PUMP

C5H6S19*K*AAA*

MAINLINE 16 SEER2 HP · source records, page 2

76 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,700–19,300BTU/h

Each efficiency range summarizes published EPA records for C5H6S19*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 76 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1676 / 76
EER2 · BTU/Wh12.5–1376 / 76
HSPF2 · BTU/Wh7.8–876 / 76
Cooling capacity · BTU/h17,700–19,30076 / 76
Heating capacity at 47°F / 8.3°C · BTU/h18,400–19,50076 / 76
Heating capacity at 17°F / −8.3°C · BTU/h10,300–11,00076 / 76
Heating capacity at 5°F / −15°C · BTU/h7,900–8,50076 / 76
COP at 5°F / −15°C1.9–276 / 76
Equipment / loop typeHP - Split System76 / 76
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)76 / 76
Compressor stagingSingle stage76 / 76
Connected capabilityNo76 / 76

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X25M17A*+ furnace: *80MS(N,L)0701716A*AHRI reference: 21772247616.008.0084002.00EPA 4509652
EA*5X25M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21772248416.008.0083002.00EPA 4509660
EA*5X25M17A*+ furnace: *80VSL0451412B*AHRI reference: 21772249216.008.0084002.00EPA 4509668
EA*5X25M17A*+ furnace: *80VSL0701412B*AHRI reference: 21772250016.008.0084002.00EPA 4509676
EA*5X25M17A*+ furnace: *80VSL0701716B*AHRI reference: 21772250816.008.0084002.00EPA 4509684
EA*5X25M17A*+WALLCON+ furnace: *97CMN0801714B*AHRI reference: 21772260416.008.0084002.00EPA 4509752
EA*5X25M17A*+ furnace: *92MSN0601412A*AHRI reference: 21772262016.008.0083002.00EPA 4509760
EA*5X25M17A*+ furnace: *92MSN0601714A*AHRI reference: 21772262816.008.0084002.00EPA 4509768
EA*5X25M17A*+ furnace: *92MSN0801716A*AHRI reference: 21772263616.008.0083002.00EPA 4509776
EA*5X25M17A*+ furnace: *95MSU0601716A*AHRI reference: 21772272516.008.0084002.00EPA 4509845
EA*5X25M17A*+WALLCON+ furnace: *80CTL0451712B*AHRI reference: 21772254015.508.0084002.00EPA 4509082
EA*5X25M17A*+WALLCON+ furnace: *80CTL0701716B*AHRI reference: 21772255615.508.0084002.00EPA 4509098
EA*5X25M17A*+WALLCON+ furnace: *80CTL0901716B*AHRI reference: 21772256415.508.0084002.00EPA 4509106
EA*5X19M17A*+ furnace: *95MSU0601716A*AHRI reference: 21772173115.507.8084001.90EPA 4509134
EA*5X19M17A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21772174715.508.0084002.00EPA 4509142
EA*5X19M17A*+WALLCON+ furnace: *97CTN0801716A*AHRI reference: 21772177115.508.0084002.00EPA 4509158
EA*5X25M17A*+WALLCON+ furnace: *96CTN0601714B*AHRI reference: 21772274115.508.0084002.00EPA 4509174
EA*5X25M17A*+WALLCON+ furnace: *97CTN0601716A*AHRI reference: 21772275715.508.0084002.00EPA 4509190
EA*5X25M17A*+WALLCON+ furnace: *97CTN0801716A*AHRI reference: 21772276515.508.0084002.00EPA 4509198
EA*5X25M17A*+ furnace: *96VTN0601412B*AHRI reference: 21772278915.508.0084002.00EPA 4509207

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →