C5H0V48*K*AAA*
ConstantComfort 20 VS HP · source records, page 18
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
ESH5X48M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215674946 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968427 → |
ESH5X48M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215675106 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3968521 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215675125 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968688 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 215675149 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968702 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 215675189 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968735 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 215675199 | 16.50 | 8.50 | 34000 | 2.06 | EPA 3968745 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 215675209 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968753 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 215675219 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968766 → |
ESH5X60M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 215675229 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968772 → |
ESH5X60M12A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215675249 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968796 → |
ESH5X60M12A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215675259 | 16.50 | 8.50 | 33600 | 2.06 | EPA 3968803 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 215675289 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3968903 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 215675299 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968918 → |
ESH5X60M12A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 215675309 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968922 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 215675329 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3968929 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 215675339 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3969011 → |
ESH5X48M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681589 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3975296 → |
ESH5X60M12A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215681669 | 16.50 | 8.50 | 33800 | 2.06 | EPA 3975323 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681679 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3975403 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681709 | 16.50 | 8.50 | 33800 | 2.08 | EPA 3975431 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →