C5H0V48*K*AAA*
ConstantComfort 20 VS HP · source records, page 14
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for C5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X48M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215675419 | 18.00 | 9.00 | 36600 | 1.98 | EPA 3969165 → |
EVM5X48M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 215675429 | 18.00 | 9.00 | 36400 | 2.02 | EPA 3969167 → |
EVM5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 215675439 | 18.00 | 9.00 | 37000 | 1.98 | EPA 3969179 → |
EVM5X48M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215675469 | 18.00 | 9.00 | 35600 | 2.00 | EPA 3969210 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 215675529 | 18.00 | 9.00 | 37600 | 1.98 | EPA 3969340 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215675759 | 18.00 | 9.00 | 37200 | 1.98 | EPA 3969362 → |
EVD5X48M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 215676119 | 18.00 | 9.00 | 36800 | 1.98 | EPA 3969849 → |
EVD5X48M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 215676159 | 18.00 | 9.00 | 35600 | 2.00 | EPA 3969938 → |
EVD5X48M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 215676099 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3970063 → |
EVD5X48M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 215676239 | 18.00 | 9.00 | 36600 | 2.02 | EPA 3970079 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 215676439 | 18.00 | 9.00 | 37600 | 1.98 | EPA 3970783 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 215676499 | 18.00 | 9.00 | 37200 | 1.98 | EPA 3970880 → |
EA*5X61M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681539 | 18.00 | 9.00 | 33600 | 2.08 | EPA 3975259 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 215681549 | 18.00 | 9.00 | 33800 | 2.08 | EPA 3975262 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 215681759 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3975550 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 215681769 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3975561 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 215681789 | 18.00 | 9.00 | 36400 | 2.00 | EPA 3975587 → |
EVM5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 215681799 | 18.00 | 9.00 | 37000 | 2.00 | EPA 3975590 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 215681369 | 18.00 | 9.00 | 34000 | 2.04 | EPA 3975828 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 215681379 | 18.00 | 9.00 | 33600 | 2.06 | EPA 3975844 → |