B5H3V36*K*AAA*
ConstantComfort 23 VS HP · source records, page 15
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218409932 | 20.50 | 9.00 | 26000 | 1.98 | EPA 4605562 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218409908 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605586 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218409900 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605594 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218409892 | 20.50 | 9.00 | 26200 | 1.96 | EPA 4605602 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218409884 | 20.50 | 9.00 | 26200 | 1.96 | EPA 4605610 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218409860 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605634 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218409852 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605642 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218409844 | 20.50 | 9.00 | 26000 | 1.96 | EPA 4605650 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218409836 | 20.50 | 9.00 | 25800 | 1.96 | EPA 4605658 → |
FCMA5B36L0C*+WALLCONCold climate designationAHRI reference: 218413172 | 20.50 | 9.50 | 25800 | 2.00 | EPA 4606322 → |
EVD5X48M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218412508 | 20.50 | 8.50 | 27600 | 2.08 | EPA 4606986 → |
EVD5X48M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218412500 | 20.50 | 8.50 | 27600 | 2.08 | EPA 4606994 → |
EVD5X42M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218412356 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607138 → |
EVD5X42M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218412348 | 20.50 | 8.50 | 28600 | 2.06 | EPA 4607146 → |
EVD5X42M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218412324 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607170 → |
EVD5X42M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218412316 | 20.50 | 8.50 | 28400 | 2.06 | EPA 4607178 → |
EVD5X42M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218412308 | 20.50 | 8.10 | 27000 | 2.00 | EPA 4607186 → |
EVD5X42M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218412292 | 20.50 | 8.50 | 28200 | 2.06 | EPA 4607202 → |
EVD5X42M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218412284 | 20.50 | 8.10 | 28600 | 2.00 | EPA 4607210 → |
EVD5X42M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218412276 | 20.50 | 8.50 | 28600 | 2.06 | EPA 4607218 → |