B5H0V48*K*AAA*
ConstantComfort 20 VS HP · source records, page 3
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218173436 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4581002 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218173427 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4581011 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218173418 | 19.00 | 9.50 | 36600 | 2.10 | EPA 4581020 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218173415 | 19.00 | 9.50 | 36600 | 2.12 | EPA 4581023 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218173412 | 19.00 | 9.00 | 36800 | 1.98 | EPA 4581026 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218173409 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4581029 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218173400 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581038 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218173397 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581041 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218173394 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581044 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218173390 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581047 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218173387 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4581050 → |
EVD5X49M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218173381 | 19.00 | 9.00 | 36400 | 2.02 | EPA 4581056 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218173378 | 19.00 | 9.00 | 36400 | 2.00 | EPA 4581059 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218173375 | 19.00 | 9.00 | 36400 | 2.00 | EPA 4581062 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218173372 | 19.00 | 9.00 | 36400 | 2.00 | EPA 4581065 → |
EVD5X49M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218173369 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4581068 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218173351 | 19.00 | 9.00 | 36200 | 2.00 | EPA 4581086 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218173348 | 19.00 | 9.00 | 36200 | 2.00 | EPA 4581089 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218173345 | 19.00 | 9.00 | 36200 | 2.00 | EPA 4581092 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218173309 | 19.00 | 9.50 | 36800 | 2.12 | EPA 4581128 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →