Day & Night / AIR-SOURCE HEAT PUMP

B5H0V48*K*AAA*

ConstantComfort 20 VS HP · source records, page 17

327 published source records · source checked Sep 21, 2026

SEER2 range15.5–19.5BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity43,500–49,000BTU/h

Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–19.5327 / 327
EER2 · BTU/Wh9–10.5327 / 327
HSPF2 · BTU/Wh8.5–9.5327 / 327
Cooling capacity · BTU/h43,500–49,000327 / 327
Heating capacity at 47°F / 8.3°C · BTU/h47,000–50,000327 / 327
Heating capacity at 17°F / −8.3°C · BTU/h41,000–47,500327 / 327
Heating capacity at 5°F / −15°C · BTU/h33,000–37,600327 / 327
COP at 5°F / −15°C1.92–2.2327 / 327
Equipment / loop typeHP - Split System327 / 327
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)327 / 327
Compressor stagingContinuously variable327 / 327
Connected capabilityNo327 / 327

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X60M12A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21817310216.008.50342001.94EPA 4597810
ESH5X60M12A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21817308416.008.50342001.94EPA 4597828
ESH5X48M12A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21817305716.008.50348001.92EPA 4597837
ESH5X48M12A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21817305416.008.50348001.92EPA 4597840
ESH5X48M12A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21817304516.008.50348001.92EPA 4597846
ESH5X60M12A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 21817307815.508.50346001.94EPA 4597831
ESH5X48M12A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 21817302115.508.50352001.92EPA 4597861