B5H0V48*K*AAA*
ConstantComfort 20 VS HP · source records, page 13
327 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 327 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 327 / 327 |
| EER2 · BTU/Wh | 9–10.5 | 327 / 327 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 327 / 327 |
| Cooling capacity · BTU/h | 43,500–49,000 | 327 / 327 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 327 / 327 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 327 / 327 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 327 / 327 |
| COP at 5°F / −15°C | 1.92–2.2 | 327 / 327 |
| Equipment / loop type | HP - Split System | 327 / 327 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 327 / 327 |
| Compressor staging | Continuously variable | 327 / 327 |
| Connected capability | No | 327 / 327 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X48M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218173138 | 18.00 | 9.00 | 36800 | 2.00 | EPA 4597777 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218173012 | 18.00 | 9.00 | 33800 | 2.08 | EPA 4597870 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218173006 | 18.00 | 9.00 | 33800 | 2.08 | EPA 4597876 → |
EA*5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218173000 | 18.00 | 9.00 | 33600 | 2.08 | EPA 4597882 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218172985 | 18.00 | 9.00 | 33800 | 2.08 | EPA 4597897 → |
EA*5X61M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218172982 | 18.00 | 9.00 | 33800 | 2.08 | EPA 4597900 → |
EA*5X61M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218172976 | 18.00 | 9.00 | 33800 | 2.08 | EPA 4597906 → |
EA*5X61M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218172973 | 18.00 | 9.00 | 33800 | 2.08 | EPA 4597909 → |
EA*5X61M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218172967 | 18.00 | 9.00 | 33600 | 2.08 | EPA 4597915 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218172955 | 18.00 | 9.00 | 33800 | 2.06 | EPA 4597927 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218172952 | 18.00 | 9.00 | 33800 | 2.06 | EPA 4597930 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218172943 | 18.00 | 9.00 | 33600 | 2.06 | EPA 4597939 → |
EA*5X60M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218172940 | 18.00 | 9.00 | 33600 | 2.06 | EPA 4597942 → |
EA*5X60M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218172937 | 18.00 | 9.00 | 33600 | 2.06 | EPA 4597945 → |
EA*5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218172934 | 18.00 | 9.00 | 33600 | 2.06 | EPA 4597948 → |
EA*5X60M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218172931 | 18.00 | 9.00 | 33600 | 2.06 | EPA 4597951 → |
EA*5X60M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218172925 | 18.00 | 9.00 | 33400 | 2.08 | EPA 4597957 → |
EA*5X60M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 218172919 | 18.00 | 9.00 | 33400 | 2.08 | EPA 4597963 → |
EA*5X60M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218172916 | 18.00 | 9.00 | 33400 | 2.08 | EPA 4597966 → |
EA*5X60M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218172913 | 18.00 | 9.00 | 33400 | 2.08 | EPA 4597969 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.