B5H0V36*K*AAA*
ConstantComfort 20 VS HP · source records, page 7
275 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 275 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19.5 | 275 / 275 |
| EER2 · BTU/Wh | 9–11.5 | 275 / 275 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 275 / 275 |
| Cooling capacity · BTU/h | 32,800–35,400 | 275 / 275 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,000 | 275 / 275 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,400–31,800 | 275 / 275 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,600–25,800 | 275 / 275 |
| COP at 5°F / −15°C | 1.64–2.04 | 275 / 275 |
| Equipment / loop type | HP - Split System | 275 / 275 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 275 / 275 |
| Compressor staging | Continuously variable | 275 / 275 |
| Connected capability | No | 275 / 275 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X37M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 218172225 | 17.50 | 9.00 | 25000 | 1.90 | EPA 4580851 → |
EA*5X37M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 218172222 | 17.50 | 9.00 | 25000 | 1.90 | EPA 4580854 → |
EA*5X37M17A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 218172216 | 17.50 | 9.00 | 25600 | 1.86 | EPA 4580860 → |
EA*5X43M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218170777 | 17.50 | 9.00 | 25200 | 1.88 | EPA 4589297 → |
EA*5X43M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218170759 | 17.50 | 9.00 | 25400 | 1.86 | EPA 4589315 → |
EA*5X42M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218170756 | 17.50 | 9.00 | 25600 | 1.84 | EPA 4589318 → |
EA*5X42M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218170753 | 17.50 | 9.00 | 25800 | 1.84 | EPA 4589321 → |
EA*5X42M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218170747 | 17.50 | 9.00 | 25600 | 1.84 | EPA 4589324 → |
EA*5X42M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218170744 | 17.50 | 9.00 | 25600 | 1.86 | EPA 4589327 → |
EA*5X42M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218170732 | 17.50 | 9.00 | 25600 | 1.84 | EPA 4589330 → |
EA*5X42M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218170729 | 17.50 | 8.50 | 25600 | 1.86 | EPA 4589333 → |
EA*5X42M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218170714 | 17.50 | 9.00 | 25600 | 1.86 | EPA 4589345 → |
EA*5X42M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218170711 | 17.50 | 9.00 | 25800 | 1.86 | EPA 4589348 → |
EA*5X37M21A*+WALLCON+ furnace: *96CTN0601714B*Cold climate designationAHRI reference: 218170699 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4589357 → |
EA*5X37M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 218170690 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4589366 → |
EA*5X37M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218170687 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4589369 → |
EA*5X37M21A*+WALLCON+ furnace: *97CMN0601714B*Cold climate designationAHRI reference: 218170684 | 17.50 | 9.00 | 25400 | 1.88 | EPA 4589372 → |
EA*5X37M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218170678 | 17.50 | 9.00 | 25200 | 1.90 | EPA 4589378 → |
EA*5X37M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 218170675 | 17.50 | 9.00 | 25200 | 1.88 | EPA 4589381 → |
EA*5X37M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 218170657 | 17.50 | 9.00 | 25400 | 1.86 | EPA 4589399 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.