Daikin / AIR-SOURCE HEAT PUMP

DH9VSA6010A*

DH9VSA

33 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity52,000–54,000BTU/h

Each efficiency range summarizes published EPA records for DH9VSA6010A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1833 / 33
EER2 · BTU/Wh9.8–10.533 / 33
HSPF2 · BTU/Wh8.5–933 / 33
Cooling capacity · BTU/h52,000–54,00033 / 33
Heating capacity at 47°F / 8.3°C · BTU/h52,500–54,00033 / 33
Heating capacity at 17°F / −8.3°C · BTU/h33,40033 / 33
Heating capacity at 5°F / −15°C · BTU/h45,000–47,00033 / 33
COP at 5°F / −15°C1.8–1.933 / 33
Equipment / loop typeHP - Split System33 / 33
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)33 / 33
Compressor stagingContinuously variable33 / 33
Connected capabilityYes33 / 33

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
DFVE60DP1300A*Cold climate designationAHRI reference: 21798910518.009.00470001.90EPA 4518351 →
DFVE60DP0300A*Cold climate designationAHRI reference: 21798911018.009.00470001.90EPA 4518355 →
CA*EA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21798911217.008.80460001.90EPA 4518357 →
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21798911417.008.80460001.90EPA 4518358 →
CA*EA6030*3A*+ furnace: D*80TC1005C*A*Cold climate designationAHRI reference: 21798912417.008.80460001.90EPA 4518368 →
CA*EA6030*3A*+ furnace: D*80TC0805D*A*Cold climate designationAHRI reference: 21798912617.008.80460001.90EPA 4518369 →
CA*EA6030*3A*+ furnace: D*80TC0805C*A*Cold climate designationAHRI reference: 21798912817.008.80460001.90EPA 4518374 →
CA*EA6030*3A*+ furnace: D*80TC0804C*A*Cold climate designationAHRI reference: 21798913017.008.80460001.90EPA 4518377 →
CA*EA6030*3A*+ furnace: D*80SC0805CUA*Cold climate designationAHRI reference: 21798913417.008.80460001.90EPA 4518380 →
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 21798913917.008.80460001.90EPA 4518383 →
CA*EA6030*3A*+ furnace: D*96TC1005CNA*Cold climate designationAHRI reference: 21798912016.508.50460001.90EPA 4518365 →
CA*EA6030*3A*+ furnace: D*96TC0804CNA*Cold climate designationAHRI reference: 21798912216.508.80460001.90EPA 4518367 →
CA*EA6030*3A*+ furnace: D*96SC0805CUA*Cold climate designationAHRI reference: 21798913216.508.80460001.90EPA 4518379 →
CA*EA6030*3A*+ furnace: D*97MC1005CNA*Cold climate designationAHRI reference: 21798913816.508.80460001.90EPA 4518384 →
CHPEA6030*3A*+MBVK20DP1X00A*Cold climate designationAHRI reference: 21798911116.008.50450001.80EPA 4518356 →
CHPEA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21798911316.008.50450001.80EPA 4518359 →
CHPEA6030*3A*+ furnace: D*96TC1205DNA*Cold climate designationAHRI reference: 21798911516.008.50450001.80EPA 4518360 →
CA*EA6030*3A*+ furnace: D*96TC1205DNA*Cold climate designationAHRI reference: 21798911616.008.50460001.90EPA 4518361 →
CHPEA6030*3A*+ furnace: D*96TC1005DNA*Cold climate designationAHRI reference: 21798911716.008.50450001.80EPA 4518362 →
CA*EA6030*3A*+ furnace: D*96TC1005DNA*Cold climate designationAHRI reference: 21798911816.008.50460001.90EPA 4518363 →