Daikin / AIR-SOURCE HEAT PUMP

DH9VSA4810A*

DH9VSA · source records, page 2

35 published source records · source checked Sep 21, 2026

SEER2 range16.2–18BTU/Wh
HSPF2 range8.5–9BTU/Wh
Cooling capacity45,000–46,000BTU/h

Each efficiency range summarizes published EPA records for DH9VSA4810A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 35 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.2–1835 / 35
EER2 · BTU/Wh10.5–11.735 / 35
HSPF2 · BTU/Wh8.5–935 / 35
Cooling capacity · BTU/h45,000–46,00035 / 35
Heating capacity at 47°F / 8.3°C · BTU/h46,000–48,00035 / 35
Heating capacity at 17°F / −8.3°C · BTU/h29,400–30,00035 / 35
Heating capacity at 5°F / −15°C · BTU/h44,00035 / 35
COP at 5°F / −15°C1.8–1.935 / 35
Equipment / loop typeHP - Split System35 / 35
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)35 / 35
Compressor stagingContinuously variable35 / 35
Connected capabilityYes35 / 35

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CHPEA4830*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21798917517.008.50440001.80EPA 4518420
CHPEA4830*3A*+ furnace: D*80TC1005C*A*Cold climate designationAHRI reference: 21798918516.508.50440001.80EPA 4518430
CHPEA4830*3A*+ furnace: D*80TC0805D*A*Cold climate designationAHRI reference: 21798918716.508.50440001.80EPA 4518432
CHPEA4830*3A*+ furnace: D*80SC0805CUA*Cold climate designationAHRI reference: 21798919516.508.50440001.80EPA 4518434
CHPEA4830*3A*+ furnace: D*80TC0805C*A*Cold climate designationAHRI reference: 21798918916.508.50440001.80EPA 4518436
CHPEA4830*3A*+ furnace: D*80TC0804C*A*Cold climate designationAHRI reference: 21798919116.508.50440001.80EPA 4518438
CHPEA4830*3A*+ furnace: D*96TC1205DNA*Cold climate designationAHRI reference: 21798917716.208.50440001.80EPA 4518422
CHPEA4830*3A*+ furnace: D*96TC1005DNA*Cold climate designationAHRI reference: 21798917916.208.50440001.80EPA 4518424
CHPEA4830*3A*+ furnace: D*96TC1005CNA*Cold climate designationAHRI reference: 21798918116.208.50440001.80EPA 4518426
CHPEA4830*3A*+ furnace: D*96TC0804CNA*Cold climate designationAHRI reference: 21798918316.208.50440001.80EPA 4518428
CHPEA4830*3A*+ furnace: D*96SC0805CUA*Cold climate designationAHRI reference: 21798919316.208.50440001.80EPA 4518440
CHPEA4830*3A*+ furnace: D*97MC1205DNA*Cold climate designationAHRI reference: 21798919716.208.50440001.80EPA 4518442
CHPEA4830*3A*+ furnace: D*97MC1005CNA*Cold climate designationAHRI reference: 21798919916.208.50440001.80EPA 4518444
CHPEA4830*3A*+ furnace: D*97MC0804CNA*Cold climate designationAHRI reference: 21798920116.208.50440001.80EPA 4518446
CHPEA4830*3A*+ furnace: D*96VC1205DNA*Cold climate designationAHRI reference: 21800303616.208.50440001.80EPA 4518546

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →