Daikin / AIR-SOURCE HEAT PUMP

DH9VSA361CA*

DH9VSA

33 published source records · source checked Sep 21, 2026

SEER2 range16.9–21BTU/Wh
HSPF2 range8.5–10BTU/Wh
Cooling capacity33,400–34,200BTU/h

Each efficiency range summarizes published EPA records for DH9VSA361CA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 33 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.9–2133 / 33
EER2 · BTU/Wh11–1233 / 33
HSPF2 · BTU/Wh8.5–1033 / 33
Cooling capacity · BTU/h33,400–34,20033 / 33
Heating capacity at 47°F / 8.3°C · BTU/h31,000–34,20033 / 33
Heating capacity at 17°F / −8.3°C · BTU/h30,800–34,20033 / 33
Heating capacity at 5°F / −15°C · BTU/h31,000–34,20033 / 33
COP at 5°F / −15°C2–2.433 / 33
Equipment / loop typeHP - Split System33 / 33
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)33 / 33
Compressor stagingContinuously variable33 / 33
Connected capabilityYes33 / 33

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CAHEA3630C3A*+MBVK16CH*X00A*Cold climate designationAHRI reference: 21669979221.0010.00342002.40EPA 3894060 →
DFVE60DP1300A*Cold climate designationAHRI reference: 21669981919.009.20330002.10EPA 3893989 →
DFVE60DP0300A*Cold climate designationAHRI reference: 21669982019.009.20330002.10EPA 3893990 →
DFVE48DP1300A*Cold climate designationAHRI reference: 21669982119.009.20330002.10EPA 3893991 →
DFVE48DP0300A*Cold climate designationAHRI reference: 21669982219.009.20330002.10EPA 3893992 →
DFVE48CP1300A*Cold climate designationAHRI reference: 21669982319.009.20330002.10EPA 3893993 →
DFVE48CP0300A*Cold climate designationAHRI reference: 21669982419.009.20330002.10EPA 3893994 →
CA*EA6030*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 21669982619.009.20326002.00EPA 3893996 →
CA*EA6030*3A*+ furnace: D*96TC1005CNA*Cold climate designationAHRI reference: 21669982819.009.20326002.00EPA 3893998 →
CA*EA6030*3A*+ furnace: D*96TC0804CNA*Cold climate designationAHRI reference: 21669983019.009.20326002.00EPA 3894000 →
CA*EA6030*3A*+ furnace: D*80TC1005C*A*Cold climate designationAHRI reference: 21669983219.009.20326002.00EPA 3894002 →
CA*EA6030*3A*+ furnace: D*80TC0805C*A*Cold climate designationAHRI reference: 21669983419.009.20326002.00EPA 3894004 →
CA*EA6030*3A*+ furnace: D*80TC0804C*A*Cold climate designationAHRI reference: 21669983619.009.20326002.00EPA 3894006 →
CA*EA6030*3A*+ furnace: D*80SC0805CUA*Cold climate designationAHRI reference: 21669983819.009.20326002.00EPA 3894008 →
CA*EA6030*3A*+ furnace: D*97MC1005CNA*Cold climate designationAHRI reference: 21669984019.009.20326002.00EPA 3894010 →
CA*EA6030*3A*+ furnace: D*97MC0804CNA*Cold climate designationAHRI reference: 21669984219.009.20326002.00EPA 3894012 →
CA*EA6030*3A*+MBVK16CP0X00A*Cold climate designationAHRI reference: 21758947019.009.20326002.00EPA 4497796 →
CA*EA6030*3A*+ furnace: D*80TC0604B*A*Cold climate designationAHRI reference: 21788307319.009.20326002.00EPA 4512501 →
CA*EA6030*3A*+ furnace: D*97MC0803BNA*Cold climate designationAHRI reference: 21788307619.009.20326002.00EPA 4512504 →
CA*EA6030*3A*+ furnace: D*80SC0604BUA*Cold climate designationAHRI reference: 21788310119.009.20326002.00EPA 4512526 →