DH7VSA2410A*
DH7VSA
90 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for DH7VSA2410A*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 90 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–19 | 90 / 90 |
| EER2 · BTU/Wh | 10.5–11 | 90 / 90 |
| HSPF2 · BTU/Wh | 8.5–8.8 | 90 / 90 |
| Cooling capacity · BTU/h | 23,200 | 90 / 90 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,200 | 90 / 90 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,800 | 90 / 90 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000 | 90 / 90 |
| COP at 5°F / −15°C | 2 | 90 / 90 |
| Equipment / loop type | HP - Split System | 90 / 90 |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) | 90 / 90 |
| Compressor staging | Continuously variable | 90 / 90 |
| Connected capability | No · Yes | 90 / 90 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
DFVE36CP1300A*Cold climate designationAHRI reference: 215415508 | 19.00 | 8.80 | 17000 | 2.00 | EPA 3624770 → |
DFVE36CP0300A*Cold climate designationAHRI reference: 215429723 | 19.00 | 8.80 | 17000 | 2.00 | EPA 3625043 → |
CA*EA3022*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 215433894 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625180 → |
CA*EA3022*3A*+MBVK12BP1X00A*Cold climate designationAHRI reference: 215433893 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625181 → |
CA*EA3626*3A*+MBVK12BP1X00A*Cold climate designationAHRI reference: 215433895 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625182 → |
CA*EA3626*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 215433896 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625183 → |
CHPEA3026*3A*+MBVK12BP1X00A*Cold climate designationAHRI reference: 215433897 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625184 → |
CHPEA3026*3A*+MBVK16CP1X00A*Cold climate designationAHRI reference: 215433898 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625185 → |
CA*EA3022*3A*+ furnace: D*97MC0603BNA*Cold climate designationAHRI reference: 215433967 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625255 → |
CA*EA3022*3A*+ furnace: D*97MC0804CNA*Cold climate designationAHRI reference: 215433969 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625256 → |
CA*EA3022*3A*+ furnace: D*97MC0803BNA*Cold climate designationAHRI reference: 215433968 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625257 → |
CA*EA3022*3A*+ furnace: D*97MC1005CNA*Cold climate designationAHRI reference: 215433970 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625258 → |
CA*EA3022*3A*+ furnace: D*80SC0604BUA*Cold climate designationAHRI reference: 215433971 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625259 → |
CA*EA3022*3A*+ furnace: D*80SC0805CUA*Cold climate designationAHRI reference: 215433972 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625260 → |
CA*EA3022*3A*+ furnace: D*96SC0603BUA*Cold climate designationAHRI reference: 215433973 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625261 → |
CA*EA3022*3A*+ furnace: D*96SC0805CUA*Cold climate designationAHRI reference: 215433974 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625262 → |
CA*EA3022*3A*+ furnace: D*80TC0603B*A*Cold climate designationAHRI reference: 215433975 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625263 → |
CA*EA3022*3A*+ furnace: D*80TC0803B*A*Cold climate designationAHRI reference: 215433976 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625264 → |
CA*EA3022*3A*+ furnace: D*80TC0804C*A*Cold climate designationAHRI reference: 215433977 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625265 → |
CA*EA3022*3A*+ furnace: D*80TC0805C*A*Cold climate designationAHRI reference: 215433978 | 19.00 | 8.60 | 17000 | 2.00 | EPA 3625266 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →