CH-RHP12-230VO
CH Series
10 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for CH-RHP12-230VO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 10 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 20–25.4 | 10 / 10 |
| EER2 · BTU/Wh | 12–13.4 | 10 / 10 |
| HSPF2 · BTU/Wh | 10–11.6 | 10 / 10 |
| Cooling capacity · BTU/h | 12,000 | 10 / 10 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 12,000–12,500 | 10 / 10 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 9,600–12,000 | 10 / 10 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,300–11,800 | 10 / 10 |
| COP at 5°F / −15°C | 1.8–2 | 10 / 10 |
| Equipment / loop type | HP - Mini or Multi Split | 10 / 10 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 10 / 10 |
| Compressor staging | Continuously variable | 10 / 10 |
| Connected capability | No | 10 / 10 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CH-PRO12MASTWM-230VICold climate designationAHRI reference: 215864174 | 25.40 | 10.50 | 11500 | 1.80 | EPA 3712329 → |
CH-RH12MASTWM-230VICold climate designationAHRI reference: 215864180 | 25.40 | 10.50 | 11500 | 1.80 | EPA 3712335 → |
CH-RSH12MMCCold climate designationAHRI reference: 215864233 | 25.00 | 10.50 | 11300 | 1.88 | EPA 3712387 → |
CH-R12MOLVWM-230VICold climate designationAHRI reference: 215864153 | 24.00 | 10.50 | 11500 | 1.80 | EPA 3712309 → |
CH-RB12MOLVWM-230VICold climate designationAHRI reference: 215864165 | 24.00 | 10.50 | 11500 | 1.80 | EPA 3712320 → |
CH-RSH06-12MCT1WCold climate designationAHRI reference: 215864253 | 23.00 | 10.00 | 11500 | 2.00 | EPA 3712404 → |
CH-RSH09-12MCTCold climate designationAHRI reference: 215864189 | 22.20 | 11.60 | 11500 | 2.00 | EPA 3712344 → |
CH-RH12MCTCold climate designationAHRI reference: 215864201 | 22.20 | 11.60 | 11500 | 2.00 | EPA 3712357 → |
CH-RS12MDT-MSCold climate designationAHRI reference: 215864214 | 20.00 | 10.00 | 11800 | 1.90 | EPA 3712370 → |
CH-RS06-12MDT- MSCold climate designationAHRI reference: 215864217 | 20.00 | 10.00 | 11800 | 1.90 | EPA 3712374 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →