Cooper&Hunter / AIR-SOURCE HEAT PUMP

CH-HPR24-230VO

CH series

13 published source records · source checked Sep 21, 2026

SEER2 range18.4–22.3BTU/Wh
HSPF2 range9.3–11.5BTU/Wh
Cooling capacity21,600–24,000BTU/h

Each efficiency range summarizes published EPA records for CH-HPR24-230VO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 13 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18.4–22.313 / 13
EER2 · BTU/Wh11–1313 / 13
HSPF2 · BTU/Wh9.3–11.513 / 13
Cooling capacity · BTU/h21,600–24,00013 / 13
Heating capacity at 47°F / 8.3°C · BTU/h23,400–29,00013 / 13
Heating capacity at 17°F / −8.3°C · BTU/h16,900–21,20013 / 13
Heating capacity at 5°F / −15°C · BTU/h21,200–27,00013 / 13
COP at 5°F / −15°C1.8–2.2113 / 13
Equipment / loop typeHP - Mini or Multi Split · HP - Split System13 / 13
Refrigerant / source-reported GWPR-410A (GWP:2088)13 / 13
Compressor stagingContinuously variable13 / 13
Connected capabilityNo13 / 13

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CH-B24MOLVWM-230VICold climate designationAHRI reference: 21079969422.3010.30230001.80EPA 2634913
CH-24MOLVWM-230VICold climate designationAHRI reference: 21079956922.3010.30230001.80EPA 2634969
CH-24MASTWM-230VICold climate designationAHRI reference: 21079955121.5011.40250002.21EPA 2634975
CH-24MSPHFC-230VICold climate designationAHRI reference: 21079960120.5011.00250002.10EPA 2634955
CH-N24MSPHCT-230VICold climate designationAHRI reference: 21079959920.5011.50258002.00EPA 2634957
CH-24MCT-WCold climate designationAHRI reference: 21326556720.5011.50258002.00EPA 2667546
CH-24MFC-WCold climate designationAHRI reference: 21326558920.5011.00250002.10EPA 2667559
CH-M24DTUICold climate designationAHRI reference: 21079960019.2010.50270002.00EPA 2634956
CH-24MDT-WCold climate designationAHRI reference: 21326557919.2010.50270002.00EPA 2667553
CH-24DKT230VICold climate designationAHRI reference: 21085726118.9010.40234001.89EPA 2634904
CH-D24MSPHWM-230VICold climate designationAHRI reference: 21079965818.9010.40234001.89EPA 2634922
CH-M24AHUCold climate designationAHRI reference: 20810123218.409.30212001.90EPA 2631960
CH-M24AHU-WCold climate designationAHRI reference: 21326560618.409.30212001.90EPA 2840058

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →