Cooper&Hunter / AIR-SOURCE HEAT PUMP

CH-HPR18-230VO

CH series

16 published source records · source checked Sep 21, 2026

SEER2 range17.6–22BTU/Wh
HSPF2 range8.9–11.3BTU/Wh
Cooling capacity16,000–18,000BTU/h

Each efficiency range summarizes published EPA records for CH-HPR18-230VO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 16 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.6–2216 / 16
EER2 · BTU/Wh11–1316 / 16
HSPF2 · BTU/Wh8.9–11.316 / 16
Cooling capacity · BTU/h16,000–18,00016 / 16
Heating capacity at 47°F / 8.3°C · BTU/h17,000–20,00016 / 16
Heating capacity at 17°F / −8.3°C · BTU/h10,900–15,60016 / 16
Heating capacity at 5°F / −15°C · BTU/h16,000–18,00016 / 16
COP at 5°F / −15°C1.75–216 / 16
Equipment / loop typeHP - Mini or Multi Split · HP - Split System16 / 16
Refrigerant / source-reported GWPR-410A (GWP:2088)16 / 16
Compressor stagingContinuously variable16 / 16
Connected capabilityNo16 / 16

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CH-B18MOLVWM-230VICold climate designationAHRI reference: 21079969322.0010.60172001.89EPA 2634914 →
CH-18MOLVWM-230VICold climate designationAHRI reference: 21079956822.0010.60172001.89EPA 2634970 →
CH-18MASTWM-230VICold climate designationAHRI reference: 21079955021.5011.30180001.80EPA 2634976 →
CH-18MSPHFC-230VICold climate designationAHRI reference: 21079959820.509.80168001.86EPA 2634958 →
CH-18MFC-WCold climate designationAHRI reference: 21326558720.509.80168001.86EPA 2667557 →
CH-16MMC-230VICold climate designationAHRI reference: 21079967720.208.90167001.76EPA 2634919 →
CH-18MSPHCT-230VICold climate designationAHRI reference: 21079959620.009.50160001.75EPA 2634960 →
CH-18MCT-WCold climate designationAHRI reference: 21326556520.009.50160001.75EPA 2667545 →
CH-18MCT1W-230VICold climate designationAHRI reference: 21085742319.8011.20167001.93EPA 2634901 →
CH-18MCT1W-WCold climate designationAHRI reference: 21326560219.8011.20167001.93EPA 2667565 →
CH-18DKT230VIAHRI reference: 21085726019.4010.00164001.90EPA 2634905 →
CH-D18MSPHWM-230VIAHRI reference: 21079965719.4010.00164001.90EPA 2634923 →
CH-M18DTUICold climate designationAHRI reference: 21079959718.009.50177001.85EPA 2634959 →
CH-18MDT-WCold climate designationAHRI reference: 21326557718.009.50177001.85EPA 2667550 →
CH-M18AHUCold climate designationAHRI reference: 20814120517.609.60170002.00EPA 2631963 →
CH-M18AHU-WCold climate designationAHRI reference: 21326560417.609.60170002.00EPA 2840056 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.