Cooper&Hunter / AIR-SOURCE HEAT PUMP

CH-ES18-230VO

CH series

14 published source records · source checked Sep 21, 2026

SEER2 range17.8–24BTU/Wh
HSPF2 range9.3–10.8BTU/Wh
Cooling capacity16,000–18,000BTU/h

Each efficiency range summarizes published EPA records for CH-ES18-230VO. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 14 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17.8–2414 / 14
EER2 · BTU/Wh11.7–13.514 / 14
HSPF2 · BTU/Wh9.3–10.814 / 14
Cooling capacity · BTU/h16,000–18,00014 / 14
Heating capacity at 47°F / 8.3°C · BTU/h17,000–20,00014 / 14
Heating capacity at 17°F / −8.3°C · BTU/h12,000–14,90014 / 14
Heating capacity at 5°F / −15°C · BTU/h11,300–13,10014 / 14
COP at 5°F / −15°C2.02–2.4414 / 14
Equipment / loop typeHP - Mini or Multi Split · HP - Split System14 / 14
Refrigerant / source-reported GWPR-410A (GWP:2088)14 / 14
Compressor stagingContinuously variable14 / 14
Connected capabilityNo14 / 14

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CH-18MOLVWM-230VICold climate designationAHRI reference: 21079956124.0010.50128002.44EPA 2545668 →
CH-B18MOLVWM-230VICold climate designationAHRI reference: 21079968924.0010.50128002.44EPA 2545686 →
CH-18MASTWM-230VIAHRI reference: 21079967223.5010.80113002.02EPA 2545714 →
CH-18MSPHFC-230VIAHRI reference: 21079958723.0010.00130002.08EPA 2545702 →
CH-18MFC-WAHRI reference: 21326558623.0010.00130002.08EPA 2667556 →
CH-16MMC-230VICold climate designationAHRI reference: 21079967622.4010.40127002.32EPA 2545945 →
CH-18MCT1W-230VIAHRI reference: 21085741921.8010.70131002.30EPA 2545701 →
CH-18MCT1W-WAHRI reference: 21326560121.8010.70131002.30EPA 2667566 →
CH-18MSPHCT-230VIAHRI reference: 21079958520.5010.50127002.16EPA 2545948 →
CH-18MCT-WAHRI reference: 21326556420.5010.50127002.16EPA 2667544 →
CH-M18DTUIAHRI reference: 21079958620.0010.60130002.40EPA 2545691 →
CH-18MDT-WAHRI reference: 21326557620.0010.60130002.40EPA 2667551 →
CH-M18AHUAHRI reference: 20810123117.809.30128002.31EPA 2631993 →
CH-M18AHU-WAHRI reference: 21326560317.809.30128002.31EPA 2840055 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →