7SHP15V18P-**A
7SHP15V Series
62 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SHP15V18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 62 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.2 | 62 / 62 |
| EER2 · BTU/Wh | 10.2–11 | 62 / 62 |
| HSPF2 · BTU/Wh | 8.1–8.8 | 62 / 62 |
| Cooling capacity · BTU/h | 17,900–18,900 | 62 / 62 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,000–18,600 | 62 / 62 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 15,000–15,600 | 62 / 62 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,600–14,000 | 62 / 62 |
| COP at 5°F / −15°C | 1.8–2 | 62 / 62 |
| Equipment / loop type | HP - Split System | 62 / 62 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 62 / 62 |
| Compressor staging | Continuously variable | 62 / 62 |
| Connected capability | No | 62 / 62 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH30AX-**+TDR+ furnace: 80G2UH045AE12*Cold climate designationAHRI reference: 218620337 | 17.20 | 8.80 | 13700 | 2.00 | EPA 4657741 → |
7E[C,U]24BX-**+TDR+ furnace: 92G1UH030BE12*Cold climate designationAHRI reference: 218620480 | 17.10 | 8.50 | 14000 | 1.90 | EPA 4657711 → |
7EH24BX-**+TDR+ furnace: 80G2UH090BE12*Cold climate designationAHRI reference: 218620491 | 16.80 | 8.40 | 13900 | 1.90 | EPA 4657802 → |
7EH30BX-**+TDR+ furnace: 80G2UH090BE12*Cold climate designationAHRI reference: 218620498 | 16.70 | 8.40 | 13900 | 1.90 | EPA 4657795 → |
7EH30AX-**+TDR+ furnace: 80G2UH070AE12*Cold climate designationAHRI reference: 218620338 | 16.50 | 8.60 | 13800 | 2.00 | EPA 4657740 → |
7EH30AX-**+TDR+ furnace: 80G2UH070AE12L*Cold climate designationAHRI reference: 218620497 | 16.50 | 8.60 | 13800 | 2.00 | EPA 4657796 → |
7EH24BX-**+TDR+ furnace: 92G1UH030BE12*Cold climate designationAHRI reference: 218620494 | 16.50 | 8.40 | 13900 | 1.90 | EPA 4657799 → |
7AH1AV18PX-230-**Cold climate designationAHRI reference: 218083037 | 16.20 | 8.50 | 12600 | 1.80 | EPA 4573173 → |
7AH1AV24PX-**Cold climate designationAHRI reference: 218615083 | 16.20 | 8.70 | 13400 | 1.90 | EPA 4657263 → |
7AH1AV18PX-**Cold climate designationAHRI reference: 218615946 | 16.20 | 8.50 | 12600 | 1.80 | EPA 4657388 → |
7EH30AX-**+TDR+ furnace: 80G1UH045AE12L*Cold climate designationAHRI reference: 218620340 | 16.20 | 8.60 | 13800 | 2.00 | EPA 4657738 → |
7EH30AX-**+TDR+ furnace: 80G1UH045AE12*Cold climate designationAHRI reference: 218620339 | 16.20 | 8.60 | 13800 | 2.00 | EPA 4657739 → |
7EH24AX-**+TDR+ furnace: 80G2UH045AE12*Cold climate designationAHRI reference: 218620327 | 16.20 | 8.40 | 13900 | 1.90 | EPA 4657749 → |
7AH1AE24PX-**Cold climate designationAHRI reference: 218615082 | 16.10 | 8.70 | 13500 | 1.90 | EPA 4657264 → |
7AH1RE24DX-**Cold climate designationAHRI reference: 218615081 | 16.10 | 8.80 | 13600 | 2.00 | EPA 4657265 → |
7AH1RE18DX-**Cold climate designationAHRI reference: 218615080 | 16.10 | 8.80 | 13600 | 2.00 | EPA 4657266 → |
7E[C,U]30AX-**+TDR+ furnace: 80G2UH070AE12L*Cold climate designationAHRI reference: 218620483 | 16.00 | 8.20 | 13900 | 1.90 | EPA 4657708 → |
7E[C,U]30AX-**+TDR+ furnace: 80G2UH070AE12*Cold climate designationAHRI reference: 218620318 | 16.00 | 8.20 | 13900 | 1.90 | EPA 4657754 → |
7EH30BX-**+TDR+ furnace: 92G1UH070BE12*Cold climate designationAHRI reference: 218620503 | 16.00 | 8.30 | 13900 | 1.90 | EPA 4657790 → |
7EH24BX-**+TDR+ furnace: 92G1UH070BE12*Cold climate designationAHRI reference: 218620496 | 16.00 | 8.30 | 13900 | 1.90 | EPA 4657797 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →