7SCP18V60P-**A
7SCP18V Series · source records, page 9
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 191 / 191 |
| EER2 · BTU/Wh | 9.6–11.7 | 191 / 191 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 191 / 191 |
| Cooling capacity · BTU/h | 42,500–55,500 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–45,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 191 / 191 |
| COP at 5°F / −15°C | 1.75–1.95 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 191 / 191 |
| Compressor staging | Continuously variable | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EH42CX-**+TDR+ furnace: 80G2UH110CE16*Cold climate designationAHRI reference: 217450565 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4046348 → |
7EH42CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217450570 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4046353 → |
7EH42CX-**+TDR+ furnace: 92G1UH110CE20*Cold climate designationAHRI reference: 217450571 | 16.00 | 8.50 | 39500 | 1.80 | EPA 4046354 → |
7EH48CX-**+TDR+ furnace: 80G1UH110CE20L*Cold climate designationAHRI reference: 217450577 | 16.00 | 8.50 | 40000 | 1.80 | EPA 4046654 → |
7EH51CX-**+TDR+ furnace: 80G2UH110CV20*Cold climate designationAHRI reference: 217897357 | 16.00 | 8.50 | 40500 | 1.85 | EPA 4512270 → |
7EH51CX-**+TDR+ furnace: 95G1UH100CE20X*Cold climate designationAHRI reference: 217897363 | 16.00 | 8.50 | 40500 | 1.85 | EPA 4512284 → |
7E[C,U]50/60CX-**+TDR+ furnace: 80G2UH110CE20L*Cold climate designationAHRI reference: 217189382 | 15.90 | 8.10 | 40500 | 1.80 | EPA 4007408 → |
7E[C,U]50/60CX-**+TDR+ furnace: 80G2UH110CE20*Cold climate designationAHRI reference: 217189383 | 15.90 | 8.10 | 40500 | 1.80 | EPA 4007410 → |
7EH42CX-**+TDR+ furnace: 95G1UH100CE20X*Cold climate designationAHRI reference: 217189367 | 15.90 | 8.50 | 40000 | 1.80 | EPA 4007454 → |
7EH50/60CX-**+TDR+ furnace: 80G1UH100CE20X*Cold climate designationAHRI reference: 217189375 | 15.90 | 8.50 | 41000 | 1.85 | EPA 4007583 → |
7EH48CX-**+TDR+ furnace: 80G2UH110CE20L*Cold climate designationAHRI reference: 217189370 | 15.90 | 8.50 | 39500 | 1.80 | EPA 4007791 → |
7EH48CX-**+TDR+ furnace: 80G2UH110CE20*Cold climate designationAHRI reference: 217189371 | 15.90 | 8.50 | 39500 | 1.80 | EPA 4007792 → |
7EH48CX-**+TDR+ furnace: 80G2UH110CE16*Cold climate designationAHRI reference: 217450573 | 15.90 | 8.50 | 39500 | 1.80 | EPA 4046281 → |
7E[C,U]50/60CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217450586 | 15.90 | 8.10 | 41000 | 1.75 | EPA 4046678 → |
7EH51CX-**+TDR+ furnace: 80G1UH100CE20X*Cold climate designationAHRI reference: 217897345 | 15.90 | 8.50 | 41000 | 1.85 | EPA 4512275 → |
7EH48CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217450578 | 15.80 | 8.50 | 40000 | 1.80 | EPA 4046655 → |
7EH48CX-**+TDR+ furnace: 96G1UH110CE20*Cold climate designationAHRI reference: 217189374 | 15.70 | 8.50 | 39500 | 1.80 | EPA 4007582 → |
7E[C,U]50/60CX-**+TDR+ furnace: 95G1UH100CE20X*Cold climate designationAHRI reference: 217189384 | 15.70 | 8.10 | 41000 | 1.75 | EPA 4007765 → |
7E[C,U]50/60CX-**+TDR+ furnace: 97G2UH090CV20*Cold climate designationAHRI reference: 217189386 | 15.70 | 8.10 | 41000 | 1.75 | EPA 4007767 → |
7E[C,U]50/60CX-**+TDR+ furnace: 96G1UH110CE20*Cold climate designationAHRI reference: 217189387 | 15.70 | 8.10 | 41500 | 1.75 | EPA 4007768 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.