7SCP18V60P-**A
7SCP18V Series · source records, page 4
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7SCP18V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 191 / 191 |
| EER2 · BTU/Wh | 9.6–11.7 | 191 / 191 |
| HSPF2 · BTU/Wh | 8.1–9.6 | 191 / 191 |
| Cooling capacity · BTU/h | 42,500–55,500 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–56,500 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–45,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 39,000–45,000 | 191 / 191 |
| COP at 5°F / −15°C | 1.75–1.95 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 191 / 191 |
| Compressor staging | Continuously variable | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]48CX-**+TDR+ furnace: 97G2UH090CE16*Cold climate designationAHRI reference: 217450551 | 16.70 | 8.50 | 39500 | 1.80 | EPA 4046603 → |
7ED48CX-**+TDR+ furnace: 97G2DF110CV20*Cold climate designationAHRI reference: 216769788 | 16.65 | 9.00 | 40000 | 1.85 | EPA 3983690 → |
7E[C,U]60DX-**+TDR+ furnace: 97G2UH135DV20*Cold climate designationAHRI reference: 216769816 | 16.65 | 8.50 | 40500 | 1.85 | EPA 3983777 → |
7E[C,U]48CX-**+TDR+ furnace: 96G1UH090CE16*Cold climate designationAHRI reference: 217189303 | 16.65 | 8.50 | 39500 | 1.80 | EPA 4007564 → |
7E[C,U]48CX-**+TDR+ furnace: 80G1UH110CE20*Cold climate designationAHRI reference: 217189309 | 16.65 | 8.50 | 39500 | 1.80 | EPA 4007645 → |
7EH42CX-**+TDR+ furnace: 96G1UH090CE16*Cold climate designationAHRI reference: 217189326 | 16.65 | 8.50 | 39500 | 1.80 | EPA 4007691 → |
7EH50/60CX-**+TDR+ furnace: 80G1UH090CE20*Cold climate designationAHRI reference: 217189356 | 16.65 | 8.50 | 40500 | 1.85 | EPA 4007732 → |
7EH50/60CX-**+TDR+ furnace: 80G1UH110CE20*Cold climate designationAHRI reference: 217189357 | 16.65 | 8.50 | 40500 | 1.85 | EPA 4007733 → |
7E[C,U]48CX-**+TDR+ furnace: 80G1UH110CE20L*Cold climate designationAHRI reference: 217450554 | 16.65 | 8.50 | 39500 | 1.80 | EPA 4046360 → |
7E[C,U]60CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217450589 | 16.65 | 8.50 | 40500 | 1.90 | EPA 4046455 → |
7EH50/60CX-**+TDR+ furnace: 80G1UH110CE20L*Cold climate designationAHRI reference: 217450592 | 16.65 | 8.50 | 40500 | 1.85 | EPA 4046458 → |
7E[C,U]49CX-**+TDR+ furnace: 97G2UH110CE20*Cold climate designationAHRI reference: 217450562 | 16.65 | 9.00 | 39500 | 1.85 | EPA 4046479 → |
7EH51CX-**+TDR+ furnace: 80G1UH110CE20L*Cold climate designationAHRI reference: 217897351 | 16.65 | 8.50 | 40500 | 1.85 | EPA 4512264 → |
7EH51CX-**+TDR+ furnace: 80G1UH090CE20*Cold climate designationAHRI reference: 217897342 | 16.65 | 8.50 | 40500 | 1.85 | EPA 4512272 → |
7EH51CX-**+TDR+ furnace: 80G1UH110CE20*Cold climate designationAHRI reference: 217897348 | 16.65 | 8.50 | 40500 | 1.85 | EPA 4512278 → |
7E[C,U]48CX-**+TDR+ furnace: 95G1UH080CE16X*Cold climate designationAHRI reference: 217189302 | 16.60 | 8.50 | 39500 | 1.80 | EPA 4007563 → |
7E[C,U]48CX-**+TDR+ furnace: 80G1UH090CE20*Cold climate designationAHRI reference: 217189308 | 16.60 | 8.50 | 39500 | 1.80 | EPA 4007644 → |
7E[C,U]49CX-**+TDR+ furnace: 80G2UH110CE16*Cold climate designationAHRI reference: 217450557 | 16.60 | 9.00 | 39000 | 1.85 | EPA 4046474 → |
7E[C,U]60CX-**+TDR+ furnace: 97G2UH090CV20*Cold climate designationAHRI reference: 216769810 | 16.55 | 8.50 | 40500 | 1.90 | EPA 3983695 → |
7E[C,U]48CX-**+TDR+ furnace: 97G2UH090CV20*Cold climate designationAHRI reference: 216769772 | 16.55 | 8.50 | 40000 | 1.80 | EPA 3983774 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →