7HP19V36P-**A
7HP19V SERIES · 7HP19V Series · A7HP19V Series · source records, page 10
198 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 7HP19V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 198 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–20 | 198 / 198 |
| EER2 · BTU/Wh | 11–13.2 | 198 / 198 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 198 / 198 |
| Cooling capacity · BTU/h | 21,600–35,800 | 198 / 198 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,800–36,000 | 198 / 198 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,900–23,000 | 198 / 198 |
| Heating capacity at 5°F / −15°C · BTU/h | 12,100–17,700 | 198 / 198 |
| COP at 5°F / −15°C | 1.48–2.2 | 198 / 198 |
| Equipment / loop type | HP - Split System | 198 / 198 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 198 / 198 |
| Compressor staging | Continuously variable | 198 / 198 |
| Connected capability | No | 198 / 198 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7E[C,U]30BX-**+TDR+ furnace: 80G2UH090BE16*AHRI reference: 217465036 | 16.00 | 8.10 | 14200 | 1.86 | EPA 4470256 → |
7E[C,U]30BX-**+TDR+ furnace: 80G2UH090BE16L*AHRI reference: 217465037 | 16.00 | 8.10 | 14200 | 1.86 | EPA 4470259 → |
7E[C,U]36CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 218329740 | 16.00 | 8.20 | 14900 | 1.94 | EPA 4584971 → |
7E[C,U]36CX-**+TDR+ furnace: 92G1UH110CE20*AHRI reference: 218329734 | 16.00 | 8.20 | 15000 | 1.94 | EPA 4584977 → |
7E[C,U]36CX-**+TDR+ furnace: 80G1UH100CE20X*AHRI reference: 218329725 | 16.00 | 8.20 | 15000 | 1.92 | EPA 4584986 → |
7E[C,U]36CX-**+TDR+ furnace: 97G2UH110CE20*AHRI reference: 218329796 | 16.00 | 8.20 | 15100 | 1.92 | EPA 4585055 → |
7E[C,U]36CX-**+TDR+ furnace: 97G1UH080CE16*AHRI reference: 218791922 | 16.00 | 7.80 | 12100 | 1.68 | EPA 4706643 → |
7EH36CX-**+TDR+ furnace: 80G1UH100CE20X*AHRI reference: 217222371 | 15.50 | 8.10 | 16500 | 2.06 | EPA 4012597 → |
7E[C,U]24BX-**+TDRAHRI reference: 217455520 | 15.50 | 8.50 | 17000 | 1.98 | EPA 4047403 → |
7E[C,U]24AX-**+TDRAHRI reference: 217455536 | 15.50 | 8.50 | 17000 | 1.98 | EPA 4047419 → |
7AH1AC30PX-**AHRI reference: 217455593 | 15.50 | 8.20 | 16200 | 1.84 | EPA 4047495 → |
7ED30/36BX-**+TDR+ furnace: 80G2DF090BE16*AHRI reference: 217464981 | 15.50 | 8.00 | 16400 | 2.10 | EPA 4470109 → |
7ED30/36BX-**+TDR+ furnace: 80G1DF090BE16*AHRI reference: 217464982 | 15.50 | 8.00 | 16300 | 2.10 | EPA 4470113 → |
7ED30/36CX-**+TDR+ furnace: 80G1DF110CE20*AHRI reference: 217464983 | 15.50 | 8.00 | 16500 | 2.12 | EPA 4470117 → |
7ED30/36CX-**+TDR+ furnace: 92G1DF090CE16*AHRI reference: 217464984 | 15.50 | 8.00 | 16400 | 2.10 | EPA 4470121 → |
7ED30/36CX-**+TDR+ furnace: 96G1DF090CE16*AHRI reference: 217464985 | 15.50 | 8.00 | 16300 | 2.12 | EPA 4470150 → |
7E[C,U]36CX-**+TDR+ furnace: 96G1UH110CE20*AHRI reference: 218329749 | 15.50 | 8.20 | 15100 | 1.92 | EPA 4584965 → |
7EH30BX-**+TDRAHRI reference: 217455521 | 15.20 | 8.10 | 15700 | 1.84 | EPA 4047404 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →