Concord / AIR-SOURCE HEAT PUMP

7HP14F48P-**A

7HP14F Series

17 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity48,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 17 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.517 / 17
EER2 · BTU/Wh12.4–1317 / 17
HSPF2 · BTU/Wh7.8–8.217 / 17
Cooling capacity · BTU/h48,00017 / 17
Heating capacity at 47°F / 8.3°C · BTU/h46,000–48,00017 / 17
Heating capacity at 17°F / −8.3°C · BTU/h29,600–30,60017 / 17
Heating capacity at 5°F / −15°C · BTU/h23,400–24,60017 / 17
COP at 5°F / −15°C2.12–2.217 / 17
Equipment / loop typeHP - Split System17 / 17
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)17 / 17
Compressor stagingSingle stage17 / 17
Connected capabilityNo17 / 17

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7AH2AV48PXC**AHRI reference: 21574704415.508.20242002.20EPA 3653237 →
7AH2AV60PXC**AHRI reference: 21574704515.508.20234002.12EPA 3653238 →
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21574707315.208.00238002.14EPA 3653218 →
7E[C,U]60CX-**+TDR+ furnace: 92G1UH110CE20*AHRI reference: 21574708215.208.00240002.12EPA 3653219 →
7E[C,U]60CX-**+TDR+ furnace: 96G1UH090CE16*AHRI reference: 21574708815.208.00242002.14EPA 3653220 →
7AH2AE48PX-**AHRI reference: 21574704215.208.20246002.20EPA 3653236 →
7E[C,U]49CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21574704715.207.80240002.14EPA 3653239 →
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CE20L*AHRI reference: 21574707515.208.10242002.14EPA 3653254 →
7E[C,U]60CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21574707815.208.00240002.12EPA 3653255 →
7E[C,U]60CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21574707915.208.00240002.12EPA 3653256 →
7E[C,U]60CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21574708115.208.00238002.12EPA 3653257 →
7E[C,U]49CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21574705615.207.80240002.12EPA 3653268 →
7E[C,U]60CX-**+TDR+ furnace: 97G2UH090CE16*AHRI reference: 21574708715.208.00242002.14EPA 3653302 →
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CE20*AHRI reference: 21574707415.208.10242002.14EPA 3653307 →
7E[C,U]60CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 21574707715.208.00242002.14EPA 3653308 →
7E[C,U]60CX-**+TDR+ furnace: 92G1UH090CE16*AHRI reference: 21574708015.208.00242002.14EPA 3653309 →
7E[C,U]60CX-**+TDR+ furnace: 80G2UH110CV20*AHRI reference: 21677953815.208.00240002.12EPA 3992801 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →