Concord / AIR-SOURCE HEAT PUMP

7HP14F42P-**A

7HP14F Series

48 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity41,000–42,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F42P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 48 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.548 / 48
EER2 · BTU/Wh12.5–13.248 / 48
HSPF2 · BTU/Wh7.8–8.248 / 48
Cooling capacity · BTU/h41,000–42,00048 / 48
Heating capacity at 47°F / 8.3°C · BTU/h39,000–40,50048 / 48
Heating capacity at 17°F / −8.3°C · BTU/h24,600–25,80048 / 48
Heating capacity at 5°F / −15°C · BTU/h19,000–20,80048 / 48
COP at 5°F / −15°C2–2.1448 / 48
Equipment / loop typeHP - Split System48 / 48
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)48 / 48
Compressor stagingSingle stage48 / 48
Connected capabilityNo48 / 48

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH42BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21574332215.507.80194002.04EPA 3652913
7E[C,U]48CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21574327515.507.80202002.12EPA 3652918
7E[C,U]48CX-**+TDR+ furnace: 80G2UH110CE20*AHRI reference: 21574327615.507.80204002.12EPA 3652919
7E[C,U]48CX-**+TDR+ furnace: 80G2UH110CE20L*AHRI reference: 21574327715.507.80204002.12EPA 3652920
7E[C,U]48CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 21574328015.507.80206002.12EPA 3652923
7E[C,U]48CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21574328115.507.80204002.10EPA 3652924
7E[C,U]48CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21574328215.507.80204002.10EPA 3652925
7E[C,U]48CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21574328515.507.80202002.10EPA 3652985
7E[C,U]48CX-**+TDR+ furnace: 96G1UH110CE20*AHRI reference: 21574328815.507.80204002.10EPA 3652986
7E[C,U]49CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21574329115.507.80193002.08EPA 3653013
7E[C,U]49CX-**+TDR+ furnace: 80G2UH110CE20*AHRI reference: 21574329215.508.00194002.06EPA 3653014
7E[C,U]49CX-**+TDR+ furnace: 80G1UH110CE20*AHRI reference: 21574329715.507.80195002.06EPA 3653016
7E[C,U]49CX-**+TDR+ furnace: 80G1UH110CE20L*AHRI reference: 21574329815.507.80195002.06EPA 3653017
7E[C,U]49CX-**+TDR+ furnace: 92G1UH090CE12*AHRI reference: 21574329915.507.80194002.04EPA 3653074
7E[C,U]49CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21574330115.507.80193002.06EPA 3653076
7E[C,U]49CX-**+TDR+ furnace: 92G1UH110CE20*AHRI reference: 21574330215.507.80196002.06EPA 3653077
7E[C,U]49CX-**+TDR+ furnace: 96G1UH110CE20*AHRI reference: 21574330415.507.80195002.06EPA 3653079
7AH1AV42PX-**AHRI reference: 21574326715.507.80206002.00EPA 3653080
7AH2AE42PX-**AHRI reference: 21574326915.508.20200002.14EPA 3653082
7AH2AE48PX-**AHRI reference: 21574327015.508.20204002.14EPA 3653083

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →