Concord / AIR-SOURCE HEAT PUMP

7HP14F36P-**A

7HP14F SERIES · 7HP14F Seies · 7HP14F Series

34 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity35,400–36,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 34 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1634 / 34
EER2 · BTU/Wh12.5–13.434 / 34
HSPF2 · BTU/Wh7.8–834 / 34
Cooling capacity · BTU/h35,400–36,00034 / 34
Heating capacity at 47°F / 8.3°C · BTU/h31,400–35,60034 / 34
Heating capacity at 17°F / −8.3°C · BTU/h20,000–21,20034 / 34
Heating capacity at 5°F / −15°C · BTU/h15,700–16,80034 / 34
COP at 5°F / −15°C1.9–2.0634 / 34
Equipment / loop typeHP - Split System34 / 34
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)34 / 34
Compressor stagingSingle stage34 / 34
Connected capabilityNo34 / 34

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]48CX-**+TDR+ furnace: 80G2UH110CE20L*AHRI reference: 21573608316.007.80165002.02EPA 3652188 →
7E[C,U]48CX-**+TDR+ furnace: 80G2UH110CE20*AHRI reference: 21573608216.007.80165002.02EPA 3652209 →
7EH42CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21573611116.007.80164001.98EPA 3652233 →
7EH42CX-**+TDR+ furnace: 80G2UH110CE20*AHRI reference: 21573611216.007.80165001.98EPA 3652234 →
7EH42CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 21573611616.007.80166002.00EPA 3652236 →
7EH42CX-**+TDR+ furnace: 80G2UH110CE20L*AHRI reference: 21573611316.007.80165001.98EPA 3652460 →
7AH2AV42PXC***AHRI reference: 21586788116.007.80163002.06EPA 3721966 →
7AH2AE42PX***AHRI reference: 21586788016.007.80163002.06EPA 3721972 →
7E[C,U]48CX-**+TDR+ furnace: 97G2UH090CE16*AHRI reference: 21573608415.507.80166001.98EPA 3652189 →
7E[C,U]48CX-**+TDR+ furnace: 80G1UH090CE20*AHRI reference: 21573608515.507.80166002.00EPA 3652190 →
7E[C,U]48CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21573608915.507.80166001.98EPA 3652191 →
7EH42BX-**+TDR+ furnace: 80G1UH070BE12*AHRI reference: 21573610015.507.80166001.96EPA 3652203 →
7EH42BX-**+TDR+ furnace: 80G1UH070BE12L*AHRI reference: 21573610115.507.80166001.96EPA 3652204 →
7EH42BX-**+TDR+ furnace: 80G1UH090BE16*AHRI reference: 21573610215.507.80166001.98EPA 3652205 →
7EH42BX-**+TDR+ furnace: 80G1UH090BE16L*AHRI reference: 21573610315.507.80166001.98EPA 3652206 →
7E[C,U]48CX-**+TDR+ furnace: 80G2UH110CE16*AHRI reference: 21573608115.507.80165002.00EPA 3652208 →
7EH42CX-**+TDR+ furnace: 92G1UH090CE16*AHRI reference: 21573612015.507.80167001.96EPA 3652226 →
7EH42CX-**+TDR+ furnace: 92G1UH110CE16*AHRI reference: 21573612115.507.80164001.96EPA 3652227 →
7EH42CX-**+TDR+ furnace: 92G1UH110CE20*AHRI reference: 21573612215.507.80168001.98EPA 3652228 →
7EH42CX-**+TDR+ furnace: 96G1UH090CE16*AHRI reference: 21573612315.507.80167001.96EPA 3652229 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →