Concord / AIR-SOURCE HEAT PUMP

7HP14F24P-**A

7HP14F SERIES · 7HP14F Series · source records, page 4

118 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,800–24,000BTU/h

Each efficiency range summarizes published EPA records for 7HP14F24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 118 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16118 / 118
EER2 · BTU/Wh12–13.8118 / 118
HSPF2 · BTU/Wh7.8–8.2118 / 118
Cooling capacity · BTU/h22,800–24,000118 / 118
Heating capacity at 47°F / 8.3°C · BTU/h20,400–23,000118 / 118
Heating capacity at 17°F / −8.3°C · BTU/h12,900–14,700118 / 118
Heating capacity at 5°F / −15°C · BTU/h10,500–11,600118 / 118
COP at 5°F / −15°C1.96–2.2118 / 118
Equipment / loop typeHP - Split System118 / 118
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)118 / 118
Compressor stagingSingle stage118 / 118
Connected capabilityNo118 / 118

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]30AX-**+TDR+ furnace: 80G2UH070AE12L*AHRI reference: 21571098315.208.00116002.14EPA 3646281
7AH2AE24PX-**AHRI reference: 21571094915.208.20112002.16EPA 3646297
7AH2AV24PXC**AHRI reference: 21571095115.208.20112002.16EPA 3646299
7EH24BX-**+TDR+ furnace: 80G2UH090BE12*AHRI reference: 21571101715.207.80105001.98EPA 3646311
7E[C,U]24AX-**+TDR+ furnace: 80G1UH040AE12X*AHRI reference: 21571095315.207.80110002.02EPA 3646312
7EH24AX-**+TDR+ furnace: 80G1UH070AE12*AHRI reference: 21571101215.207.80107001.98EPA 3646320
7EH24AX-**+TDR+ furnace: 80G1UH070AE12L*AHRI reference: 21571101315.207.80107001.98EPA 3646321
7EH24BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21571101415.208.00108001.98EPA 3646322
7ED30/36BX-**+TDR+ furnace: 80G2DF090BE16*AHRI reference: 21571106515.208.20114002.10EPA 3646378
7E[C,U]24BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21571097515.207.80110002.02EPA 3646383
7EH30BX-**+TDR+ furnace: 95G1UH060BE12X*AHRI reference: 21571104215.208.00112002.04EPA 3646412
7EH30BX-**+TDR+ furnace: 97G2UH045BE12*AHRI reference: 21571104615.207.80112002.04EPA 3646416
7EH30BX-**+TDR+ furnace: 97G2UH070BE12*AHRI reference: 21571104715.207.80112002.04EPA 3646417
7E[C,U]30BX-**+TDR+ furnace: 80G1UH080BE16X*AHRI reference: 21571098815.208.00115002.12EPA 3646428
7EH30BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21571105315.208.00112002.06EPA 3646474
7E[C,U]24AX-**+TDR+ furnace: 80G1UH060AE12X*AHRI reference: 21571095415.207.80110002.02EPA 3646489
7E[C,U]24AX-**+TDR+ furnace: 80G2UH070AE12*AHRI reference: 21571095615.207.80110002.02EPA 3646490
7E[C,U]30BX-**+TDR+ furnace: 92G1UH045BE12*AHRI reference: 21571100115.208.00116002.14EPA 3646499
7E[C,U]24BX-**+TDR+ furnace: 80G2UH090BE12*AHRI reference: 21571096515.207.80110002.02EPA 3646513
7E[C,U]24BX-**+TDR+ furnace: 92G1UH070BE12*AHRI reference: 21571097615.207.80110002.04EPA 3646516

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.