Concord / AIR-SOURCE HEAT PUMP

4HP18V60P

4HP18V SERIES

20 published source records · source checked Sep 21, 2026

SEER2 range16–17.1BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity46,000–46,500BTU/h

Each efficiency range summarizes published EPA records for 4HP18V60P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 20 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–17.120 / 20
EER2 · BTU/Wh11–11.720 / 20
HSPF2 · BTU/Wh7.8–8.520 / 20
Cooling capacity · BTU/h46,000–46,50020 / 20
Heating capacity at 47°F / 8.3°C · BTU/h46,000–46,50020 / 20
Heating capacity at 17°F / −8.3°C · BTU/h30,400–36,00020 / 20
Heating capacity at 5°F / −15°C · BTU/h26,000–28,80020 / 20
COP at 5°F / −15°C1.8–2.120 / 20
Equipment / loop typeHP - Split System20 / 20
Refrigerant / source-reported GWPR-410A (GWP:2088)20 / 20
Compressor stagingContinuously variable20 / 20
Connected capabilityNo20 / 20

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P48C+TDR+TXV+ furnace: 97G2UH090CV20AHRI reference: 21410024617.107.80270001.80EPA 4011296
EAH1P48C+TDR+TXV+ furnace: 97G2UH110CV20AHRI reference: 21410024717.107.80268001.80EPA 4011347
7EH48CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21473065617.107.80270001.80EPA 4011381
7EH48CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21473065817.107.80268001.80EPA 4011382
EA(C,U)1P49C+TDR+TXV+ furnace: 97G2UH090CV20AHRI reference: 21410024216.507.80266001.90EPA 4011292
EA(C,U)1P49C+TDR+TXV+ furnace: 97G2UH110CV20AHRI reference: 21410024316.507.80262001.90EPA 4011293
EAC4X49C+TDR+ furnace: 97G2UH090CV20AHRI reference: 21410024416.507.80266001.90EPA 4011294
EAC4X49C+TDR+ furnace: 97G2UH110CV20AHRI reference: 21410024516.507.80262001.90EPA 4011295
EAD4X-50/60C+TDR+ furnace: 97G2DF110CV20AHRI reference: 21410023316.508.50288002.08EPA 4011346
7ED50/60CX-0*+TDR+ furnace: 97G2DF110CV20AHRI reference: 21473052416.508.50288002.08EPA 4011375
7EC49CX-0*+TDR+ furnace: 97G2UH090CV20AHRI reference: 21473062316.507.80266001.90EPA 4011378
7EC49CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21473062516.507.80262001.90EPA 4011380
EA(C,U)1P49C+H4TXV02+ furnace: 92G1UH110CE20AHRI reference: 20690702716.007.80260001.92EPA 2448165
EAC4X49C+ furnace: 92G1UH110CE20AHRI reference: 20690708916.007.80260001.92EPA 2448170
7EC49CX-0*+TDR+ furnace: 92G1UH110CE20AHRI reference: 21473061916.007.80260001.92EPA 3493009
EA(C,U)1P49C+TDR+TXV+ furnace: 97G2UH110CE20AHRI reference: 21393430016.007.80262001.90EPA 4011335
EAC4X49C+TDR+ furnace: 97G2UH110CE20AHRI reference: 21393430216.007.80262001.90EPA 4011336
EAD4X-50/60C+TDR+ furnace: 97G2DF110CE20AHRI reference: 21393437316.008.50286002.10EPA 4011342
7ED50/60CX-0*+TDR+ furnace: 97G2DF110CE20AHRI reference: 21473052016.008.50286002.10EPA 4011371
7EC49CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21473062416.007.80262001.90EPA 4011379

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →