Concord / AIR-SOURCE HEAT PUMP

4HP18V36P

4HP18V SERIES · source records, page 7

192 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,000–34,800BTU/h

Each efficiency range summarizes published EPA records for 4HP18V36P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19192 / 192
EER2 · BTU/Wh11–12.3192 / 192
HSPF2 · BTU/Wh7.8–8.5192 / 192
Cooling capacity · BTU/h22,000–34,800192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h22,000–34,800192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h14,900–24,800192 / 192
Heating capacity at 5°F / −15°C · BTU/h14,100–20,000192 / 192
COP at 5°F / −15°C1.78–2.18192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-410A (GWP:2088)192 / 192
Compressor stagingContinuously variable192 / 192
Connected capabilityNo192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ED1P30/36B+H4TXV02+ furnace: 92G1DF070BE12AHRI reference: 20690659318.008.10181002.02EPA 2448149 →
ED1P30/36B+H4TXV02+ furnace: 96G1DF045BE12AHRI reference: 20690659618.008.10179002.04EPA 2448150 →
ED1P30/36B+H4TXV02+ furnace: 92G1DF045BE12AHRI reference: 20690659218.008.10181002.04EPA 2448159 →
EAC4X24B+ furnace: 96G1UH070BE12AHRI reference: 20690639618.007.80156001.94EPA 2448264 →
EAC4X30B+ furnace: 95G1UH045BE12AHRI reference: 20690641418.008.10151001.97EPA 2448282 →
7EH30BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21473048818.008.10152001.99EPA 3493021 →
7EH30BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21473049318.008.50153002.03EPA 3493025 →
7EH30BX-0*+TDR+ furnace: 96G2UH045BE12AHRI reference: 21473056318.008.50152002.02EPA 3493026 →
7EH30BX-0*+TDR+ furnace: 96G2UH070BE12AHRI reference: 21473056518.008.50152002.02EPA 3493028 →
7EC30BX-0*+TDR+ furnace: 95G1UH045BE12AHRI reference: 21473042818.008.10151001.97EPA 3493053 →
7EC24BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21473038018.007.80156001.93EPA 3493168 →
7EC24BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21473038118.007.80156001.94EPA 3493169 →
7AH2AE24PX-0*AHRI reference: 21521900018.008.50152002.10EPA 3554738 →
7EC30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21473043918.008.10151002.06EPA 4010677 →
7EH30BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21473056818.008.50152002.11EPA 4010679 →
7EH48BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21473058918.008.50170001.99EPA 4010684 →
7EH48CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21473060318.008.10167001.95EPA 4010687 →
EA(C,U)1P30B+TDR+TXV+ furnace: 97G2UH070BE12AHRI reference: 21393414318.008.10151002.06EPA 4010710 →
EAC4X30B+TDR+ furnace: 97G2UH070BE12AHRI reference: 21393414918.008.10151002.06EPA 4010714 →
EAH1P30B+TDR+TXV+ furnace: 97G2UH045BE12AHRI reference: 21393415018.008.50152002.11EPA 4010715 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →