Concord / AIR-SOURCE HEAT PUMP

4HP17L48P-**A

4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 6

150 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.6BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity46,000–48,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 150 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.6150 / 150
EER2 · BTU/Wh12.5–13150 / 150
HSPF2 · BTU/Wh8–8.5150 / 150
Cooling capacity · BTU/h46,000–48,000150 / 150
Heating capacity at 47°F / 8.3°C · BTU/h44,500–47,000150 / 150
Heating capacity at 17°F / −8.3°C · BTU/h30,000–31,600150 / 150
Heating capacity at 5°F / −15°C · BTU/h24,200–25,600150 / 150
COP at 5°F / −15°C2.16–2.38150 / 150
Equipment / loop typeHP - Split System150 / 150
Refrigerant / source-reported GWPR-410A (GWP:2088)150 / 150
Compressor stagingSingle stage150 / 150
Connected capabilityNo150 / 150

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X48C+TDR+ furnace: 92G1UH110CE16AHRI reference: 21032590515.208.10244002.18EPA 2462138
EA(C;U)1P50/60C+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21032587315.208.00242002.18EPA 2462140
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173696815.208.10246002.16EPA 2462828
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21173698215.208.00246002.18EPA 2463279
EAH1P48C*+TDR+TXV+ furnace: 96G1UH110CE20AHRI reference: 21173714915.208.00248002.18EPA 2463702
EAH1P48C*+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21173699515.208.00246002.18EPA 2467982
EAH1P51C*+TDR+TXV+ furnace: 92G1UH090CE16AHRI reference: 21173727015.208.30256002.30EPA 2468411
EAH1P51C*+TDR+TXV+ furnace: 80G1UH110CE20AHRI reference: 21173726115.208.30256002.30EPA 2468421
EAH1P48C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173707415.208.00244002.18EPA 2468859
EAH1P60D*+TDR+TXV+ furnace: 96G1UH135DE20AHRI reference: 21173733915.208.10246002.20EPA 2468872
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CV20AHRI reference: 21173730915.208.30256002.28EPA 2468875
EAH1P51C*+TDR+TXV+ furnace: 92G1UH110CE20AHRI reference: 21173728615.208.30256002.28EPA 2469333
7EC48CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471181915.208.10244002.20EPA 3485337
7EC48BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21471181415.208.10242002.18EPA 3485347
7EC48BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21471181515.208.10242002.18EPA 3485401
7EC60CX-0*+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21471187415.208.10254002.38EPA 3485464
7EC49CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21471184115.208.10254002.24EPA 3485598
7EC49CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21471184415.208.10254002.24EPA 3485645
7EC49CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21471184715.208.10256002.26EPA 3485650
7EC49CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21471184815.208.10256002.26EPA 3485652

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →