Concord / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 14

297 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 297 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8297 / 297
EER2 · BTU/Wh12.2–14297 / 297
HSPF2 · BTU/Wh7.8–8.7297 / 297
Cooling capacity · BTU/h34,800–36,000297 / 297
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000297 / 297
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800297 / 297
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200297 / 297
COP at 5°F / −15°C2.06–2.36297 / 297
Equipment / loop typeHP - Split System297 / 297
Refrigerant / source-reported GWPR-410A (GWP:2088)297 / 297
Compressor stagingSingle stage297 / 297
Connected capabilityNo297 / 297

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7ED30/36CX-0*+TDR+ furnace: 97G2DF090CE16AHRI reference: 21471152715.808.00186002.14EPA 3491761 →
7AH1AV36PX-0*AHRI reference: 21486566915.808.10174002.20EPA 3553775 →
7AH2AE36PX-0*AHRI reference: 21486567115.808.10185002.28EPA 3553776 →
BCE5C42M*4XAHRI reference: 21117440715.608.10176002.16EPA 2454722 →
EA(C;U)1P36B+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21032604415.607.80174002.12EPA 2457858 →
EAC4X36B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21032619715.607.80174002.12EPA 2459272 →
EAH1P48B*+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21173644215.607.80175002.20EPA 2463665 →
EAH1P48B*+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21173647115.607.80174002.18EPA 2464488 →
EAH1P48B*+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21173627915.607.80175002.20EPA 2465748 →
EAH1P48B*+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21173648815.607.80174002.18EPA 2466627 →
EAD4X-30/36B+TDR+ furnace: 80G2DF090BE16AHRI reference: 21326513215.608.00187002.12EPA 2839775 →
7EH42BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21471144215.608.10188002.18EPA 3486031 →
7EH42BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21471144315.608.10189002.26EPA 3486034 →
7EH48BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21471147815.607.80175002.20EPA 3486075 →
7EH48BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 21471149215.607.80175002.20EPA 3486103 →
7EH48BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21471149415.607.80174002.18EPA 3486105 →
7EH42BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21471144815.608.00187002.20EPA 3486117 →
7ED30/36CX-0*+TDR+ furnace: 97G2DF110CE20AHRI reference: 21471152915.608.00189002.12EPA 3486125 →
7EC36BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21471157015.607.80174002.12EPA 3486181 →
7ED30/36BX-0*+TDR+ furnace: 80G2DF090BE16AHRI reference: 21471151915.608.00187002.12EPA 3486194 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →