Concord / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series

297 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 297 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8297 / 297
EER2 · BTU/Wh12.2–14297 / 297
HSPF2 · BTU/Wh7.8–8.7297 / 297
Cooling capacity · BTU/h34,800–36,000297 / 297
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000297 / 297
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800297 / 297
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200297 / 297
COP at 5°F / −15°C2.06–2.36297 / 297
Equipment / loop typeHP - Split System297 / 297
Refrigerant / source-reported GWPR-410A (GWP:2088)297 / 297
Compressor stagingSingle stage297 / 297
Connected capabilityNo297 / 297

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC48CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471157916.808.00168002.12EPA 3485489
7EH42CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471145816.808.00176002.22EPA 3485591
7EC48CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471158016.808.00170002.18EPA 3486036
7EC48CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471158116.808.00170002.18EPA 3486037
7EC48CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471158816.807.80168002.14EPA 3486269
EA(C;U)1P36B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21044204416.607.80168002.14EPA 2458856
EAC4X36B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21032618016.607.80168002.14EPA 2460357
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE20AHRI reference: 21173658216.608.10175002.24EPA 2466183
EAH1P51C*+TDR+TXV+ furnace: 80G1UH090CE20AHRI reference: 21173669016.608.00174002.22EPA 2467968
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE16AHRI reference: 21173656916.608.00171002.20EPA 2468830
EAH1P51C*+TDR+TXV+ furnace: 80G2UH110CE20LAHRI reference: 21173659516.608.10175002.24EPA 2468851
EAD4X-48C+TDR+ furnace: 80G1DF110CE20AHRI reference: 21326514816.608.70188002.34EPA 2840034
7EC48CX-0*+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21471157816.607.80170002.16EPA 3485485
7EH42CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471145916.608.10181002.24EPA 3485596
7EH51CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471150116.608.00171002.20EPA 3485728
7EH51CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471150216.608.10175002.24EPA 3485729
7EH51CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471150316.608.10175002.24EPA 3485731
7EH51CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471150916.608.00174002.22EPA 3486051
7ED48CX-0*+TDR+ furnace: 80G1DF110CE20AHRI reference: 21471154016.608.70188002.34EPA 3486062
7EH42CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471146016.608.10181002.24EPA 3486137

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →