SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21471137515.808.00141002.20EPA 3485228 →
7EC30AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21471137615.808.00141002.20EPA 3485229 →
7EH36CX-0*+TDR+ furnace: 80G1UH090CE20AHRI reference: 21471134915.808.50148002.26EPA 3485245 →
7EH30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471130815.807.80138002.00EPA 3485251 →
7EH36CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21471135415.808.30147002.24EPA 3485257 →
7EH36CX-0*+TDR+ furnace: 80G2UH110CE16AHRI reference: 21471134115.808.30145002.22EPA 3485282 →
7EH36CX-0*+TDR+ furnace: 97G2UH090CE16AHRI reference: 21471134415.808.30145002.20EPA 3485290 →
7EH30BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21471132315.807.80136002.08EPA 3485294 →
7ED42BX-0*+TDR+ furnace: 80G2DF090BE16AHRI reference: 21471136015.808.60151002.32EPA 3485330 →
7EH30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21471132615.808.00137002.08EPA 3485338 →
7EC36BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21471142115.808.00143002.20EPA 3485416 →
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471139015.808.00144002.22EPA 3485421 →
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21471139115.808.00144002.22EPA 3485423 →
7EC36AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21471140215.808.00144002.26EPA 3485455 →
7EC36BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21471141915.808.10143002.24EPA 3485511 →
7EC36AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21471140315.808.00144002.26EPA 3485529 →
7EH30BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21471131915.807.80138002.08EPA 3485573 →
7EC36AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21471141115.808.10144002.26EPA 3485574 →
7EC36BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21471141515.808.10142002.26EPA 3485640 →
7EC36BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21471142715.808.10142002.26EPA 3485641 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.