Concord / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 2

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC36BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 21471142616.208.10141002.26EPA 3485586
7ED42BX-0*+TDR+ furnace: 80G1DF090BE16AHRI reference: 21471136516.208.60148002.34EPA 3485670
7EH30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471132716.207.80134002.12EPA 3491633
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032631516.008.10143002.28EPA 2455465
EA(C;U)1P36B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21032632216.008.10144002.28EPA 2455479
EA(C;U)1P36B+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21032633316.008.10144002.28EPA 2455620
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032631116.008.10144002.28EPA 2455658
EAC4X36A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21032640416.008.10144002.28EPA 2455661
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21032631016.008.10144002.28EPA 2457623
EA(C;U)1P36A+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 21032630916.008.10143002.26EPA 2457635
EAC4X30B+TDR+ furnace: 80G2UH090BE16AHRI reference: 21032638216.008.00142002.22EPA 2457636
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21032628916.008.00142002.22EPA 2458098
EAC4X36B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21032641416.008.10144002.28EPA 2458403
EAC4X36A+TDR+ furnace: 80G2UH070AE12AHRI reference: 21032640016.008.10143002.26EPA 2458410
EAC4X30B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21032638116.008.00142002.22EPA 2458475
EA(C;U)1P30B+TDR+TXV+ furnace: 80G2UH090BE16AHRI reference: 21032629016.008.00142002.22EPA 2458597
EAC4X36A+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21032640116.008.10143002.26EPA 2459013
EAC4X36B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21032642216.008.10143002.26EPA 2459250
EA(C;U)1P36A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032631216.008.10144002.28EPA 2459256
EAC4X36B+TDR+ furnace: 80G2UH090BV16AHRI reference: 21032642516.008.10144002.28EPA 2459734

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →