Concord / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 10

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21471137715.608.00144002.20EPA 3485232
7EC30AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21471137815.608.00144002.20EPA 3485234
7EH36CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21471134715.608.50148002.24EPA 3485237
7EH36CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21471135015.608.30146002.22EPA 3485246
7EH36CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21471135115.608.30146002.22EPA 3485249
7EH36CX-0*+TDR+ furnace: 92G1UH090CE12AHRI reference: 21471135215.608.30147002.24EPA 3485253
7EH36CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21471135315.608.30146002.24EPA 3485255
7EH36CX-0*+TDR+ furnace: 80G2UH110CE20AHRI reference: 21471134215.608.50148002.22EPA 3485283
7EH36CX-0*+TDR+ furnace: 80G2UH110CE20LAHRI reference: 21471134315.608.50148002.22EPA 3485287
7EH36CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21471134515.608.30147002.22EPA 3485293
7EH30BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21471132415.607.80137002.06EPA 3485298
7EH30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21471132515.607.80136002.06EPA 3485312
7EH36CX-0*+TDR+ furnace: 92G1UH110CE20AHRI reference: 21471135515.608.50148002.24EPA 3485317
7EH36CX-0*+TDR+ furnace: 96G1UH090CE16AHRI reference: 21471135615.608.30145002.22EPA 3485322
7EH36CX-0*+TDR+ furnace: 96G1UH110CE20AHRI reference: 21471135715.608.50148002.26EPA 3485324
7ED42BX-0*+TDR+ furnace: 97G2DF045BE12AHRI reference: 21471136115.608.50151002.32EPA 3485332
7ED42BX-0*+TDR+ furnace: 97G2DF070BE16AHRI reference: 21471136215.608.50151002.32EPA 3485333
7EC36BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21471142015.608.10145002.26EPA 3485361
7EC30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21471137915.608.00145002.20EPA 3485388
7EC30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21471138915.608.00145002.18EPA 3485419