Concord / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 12

257 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17257 / 257
EER2 · BTU/Wh12.5–14257 / 257
HSPF2 · BTU/Wh7.8–8.2257 / 257
Cooling capacity · BTU/h22,400–24,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700257 / 257
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500257 / 257
COP at 5°F / −15°C2–2.18257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7AH1AV24PX-0*AHRI reference: 21486565415.808.00108002.12EPA 3553837
7AH2AE24PX-0*AHRI reference: 21486565615.808.10104002.12EPA 3553938
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032647415.607.80106002.00EPA 2471033
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032647315.607.80106002.00EPA 2471467
EA(C;U)1P30B+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21032647615.607.80106002.00EPA 2471474
EA(C;U)1P30B+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21032647515.607.80106002.00EPA 2471477
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032644515.607.80108002.00EPA 2471669
BCE7E30M*4XAHRI reference: 21185563315.608.10108002.16EPA 2471768
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032644615.607.80108002.00EPA 2471774
EA(C;U)1P24B+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21032644815.607.80108002.00EPA 2471992
EAD4X-30/36C+TDR+ furnace: 80G1DF110CE20AHRI reference: 21326512015.608.20114002.08EPA 2648769
EAD4X-30/36B+TDR+ furnace: 96G1DF045BE12AHRI reference: 21326511715.608.20114002.08EPA 2648904
EAC4X24B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032655115.607.80108002.00EPA 2836718
EAC4X30B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032657915.607.80106002.00EPA 2836730
EAC4X24B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032655215.607.80108002.00EPA 2836737
EAC4X30B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21032657815.607.80106002.00EPA 2836749
EAC4X24B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032655315.607.80108002.00EPA 2836759
EAC4X30B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032658015.607.80106002.00EPA 2836761
EAC4X24B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21032655015.607.80108002.00EPA 2836806
EAC4X30B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032658115.607.80106002.00EPA 2836816

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →