4HP17L24P-**A
4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 10
257 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.4–17 | 257 / 257 |
| EER2 · BTU/Wh | 12.5–14 | 257 / 257 |
| HSPF2 · BTU/Wh | 7.8–8.2 | 257 / 257 |
| Cooling capacity · BTU/h | 22,400–24,000 | 257 / 257 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,000–22,600 | 257 / 257 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,400–14,700 | 257 / 257 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,200–11,500 | 257 / 257 |
| COP at 5°F / −15°C | 2–2.18 | 257 / 257 |
| Equipment / loop type | HP - Split System | 257 / 257 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 257 / 257 |
| Compressor staging | Single stage | 257 / 257 |
| Connected capability | No | 257 / 257 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
7EC30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 214711302 | 16.00 | 7.80 | 10200 | 2.00 | EPA 3485694 → |
7EC30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 214711305 | 16.00 | 7.80 | 10400 | 2.00 | EPA 3485701 → |
7EC30AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 214711275 | 16.00 | 7.80 | 10600 | 2.04 | EPA 3485704 → |
7ED30/36BX-0*+TDR+ furnace: 80G1DF070BE12AHRI reference: 214711228 | 16.00 | 8.10 | 11200 | 2.10 | EPA 3491834 → |
7AH1AE24PX-0*AHRI reference: 214865724 | 16.00 | 7.80 | 10400 | 2.08 | EPA 3553703 → |
7AH1AE30PX-0*AHRI reference: 214865726 | 16.00 | 8.10 | 10800 | 2.06 | EPA 3553704 → |
7AH1AV30PX-0*AHRI reference: 214865707 | 16.00 | 8.10 | 10400 | 2.06 | EPA 3553801 → |
7AH2AE30PX-0*AHRI reference: 214865709 | 16.00 | 8.20 | 10800 | 2.16 | EPA 3553802 → |
EAC4X24A+TDR+ furnace: 80G2UH070AE12AHRI reference: 210326540 | 16.00 | 7.80 | 10600 | 2.02 | EPA 3984527 → |
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AE12AHRI reference: 211734945 | 16.00 | 7.80 | 10500 | 2.04 | EPA 3990322 → |
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 210326470 | 15.80 | 7.80 | 10600 | 2.00 | EPA 2471043 → |
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 210326484 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2471468 → |
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 210326464 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2471476 → |
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AE12AHRI reference: 210326463 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2471576 → |
EA(C;U)1P24B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 210326456 | 15.80 | 7.80 | 10600 | 2.02 | EPA 2471577 → |
EAH1P24A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 211734922 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2471943 → |
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 210326442 | 15.80 | 7.80 | 10600 | 2.00 | EPA 2471998 → |
BCE5V24M*4XAHRI reference: 210326430 | 15.80 | 8.00 | 10800 | 2.12 | EPA 2472001 → |
EAH1P24A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 211734913 | 15.80 | 7.80 | 10600 | 2.04 | EPA 2472495 → |
EAD4X-30/36B+TDR+ furnace: 92G1DF070BE12AHRI reference: 213265116 | 15.80 | 8.20 | 11200 | 2.06 | EPA 2648905 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →