4HP17L24P-**A
4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series
257 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.4–17 | 257 / 257 |
| EER2 · BTU/Wh | 12.5–14 | 257 / 257 |
| HSPF2 · BTU/Wh | 7.8–8.2 | 257 / 257 |
| Cooling capacity · BTU/h | 22,400–24,000 | 257 / 257 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,000–22,600 | 257 / 257 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,400–14,700 | 257 / 257 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,200–11,500 | 257 / 257 |
| COP at 5°F / −15°C | 2–2.18 | 257 / 257 |
| Equipment / loop type | HP - Split System | 257 / 257 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 257 / 257 |
| Compressor staging | Single stage | 257 / 257 |
| Connected capability | No | 257 / 257 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EAH1P30B*+TDR+TXV+ furnace: 80G2UH090BE16LAHRI reference: 211735158 | 17.00 | 8.00 | 10300 | 2.06 | EPA 2471254 → |
EAH1P30B*+TDR+TXV+ furnace: 80G2UH090BE16AHRI reference: 211735149 | 17.00 | 8.00 | 10300 | 2.06 | EPA 2471266 → |
EAH1P30B*+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 211735230 | 17.00 | 8.00 | 10400 | 2.10 | EPA 2837323 → |
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 214711215 | 17.00 | 8.00 | 10400 | 2.10 | EPA 3485323 → |
7EH30BX-0*+TDR+ furnace: 80G1UH090BE16LAHRI reference: 214711216 | 17.00 | 8.00 | 10400 | 2.10 | EPA 3485325 → |
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 214711207 | 17.00 | 8.00 | 10300 | 2.06 | EPA 3485662 → |
7EH30BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 214711208 | 17.00 | 8.00 | 10300 | 2.06 | EPA 3485663 → |
EAH1P30B*+TDR+TXV+ furnace: 80G2UH090BE12AHRI reference: 211735138 | 16.80 | 7.80 | 10300 | 2.06 | EPA 2471262 → |
EAH1P30B*+TDR+TXV+ furnace: 80G1UH070BE12AHRI reference: 211735212 | 16.80 | 8.00 | 10400 | 2.06 | EPA 2837329 → |
7EH30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 214711212 | 16.80 | 7.80 | 10400 | 2.08 | EPA 3485319 → |
7EH30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 214711213 | 16.80 | 8.00 | 10400 | 2.06 | EPA 3485320 → |
7EH30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 214711214 | 16.80 | 8.00 | 10400 | 2.06 | EPA 3485321 → |
7EH30BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 214711206 | 16.80 | 7.80 | 10300 | 2.06 | EPA 3485660 → |
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 210326483 | 16.60 | 8.00 | 10400 | 2.06 | EPA 2471040 → |
EAH1P30A*+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 211735044 | 16.60 | 8.10 | 10400 | 2.12 | EPA 2471600 → |
EAC4X30B+TDR+ furnace: 80G1UH090BE16AHRI reference: 210326588 | 16.60 | 8.00 | 10400 | 2.06 | EPA 2836765 → |
EAH1P30B*+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 211735274 | 16.60 | 8.00 | 10600 | 2.06 | EPA 2837313 → |
7EH30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 214711194 | 16.60 | 8.10 | 10400 | 2.12 | EPA 3484970 → |
7EH30BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 214711219 | 16.60 | 8.00 | 10600 | 2.06 | EPA 3485212 → |
7EC30BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 214711297 | 16.60 | 8.00 | 10400 | 2.06 | EPA 3485549 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →