Concord / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 8

256 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8256 / 256
EER2 · BTU/Wh12.2–14256 / 256
HSPF2 · BTU/Wh7.8–8.5256 / 256
Cooling capacity · BTU/h18,000256 / 256
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000256 / 256
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100256 / 256
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700256 / 256
COP at 5°F / −15°C1.9–2.16256 / 256
Equipment / loop typeHP - Split System256 / 256
Refrigerant / source-reported GWPR-410A (GWP:2088)256 / 256
Compressor stagingSingle stage256 / 256
Connected capabilityNo256 / 256

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7ED30/36BX-0*+TDR+ furnace: 96G1DF070BE16AHRI reference: 21471111016.208.4090002.08EPA 3485685 →
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21032661316.008.1084002.08EPA 2455616 →
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH045AE12AHRI reference: 21032660216.008.1084002.06EPA 2455622 →
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032661016.008.0082002.08EPA 2455667 →
EAC4X30A+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21032673516.007.8075001.92EPA 2455836 →
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032660316.008.1085002.06EPA 2455842 →
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21032663816.007.8078001.96EPA 2455860 →
EAC4X24A+TDR+ furnace: 80G2UH045AE12AHRI reference: 21032671516.008.1084002.06EPA 2455864 →
EAC4X24B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032671916.008.0082002.06EPA 2455868 →
BCE5E24M*4XAHRI reference: 21117446216.008.1085002.14EPA 2456983 →
BCE5V18M*4XAHRI reference: 21032659216.008.1082002.08EPA 2456988 →
EAC4X30A+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21032673616.007.8075001.92EPA 2457627 →
EAC4X24B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21032671816.008.0082002.04EPA 2457633 →
EAC4X24B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032673016.008.0082002.04EPA 2457866 →
EAC4X30A+TDR+ furnace: 80G2UH045AE12AHRI reference: 21032673916.007.8079001.98EPA 2457894 →
EAC4X24B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032672316.008.0082002.08EPA 2458099 →
EAC4X30B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21032675116.007.8078001.96EPA 2458147 →
EAC4X24B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21032672116.008.0082002.06EPA 2458152 →
EAC4X24B+TDR+ furnace: 80G2UH090BV16AHRI reference: 21032673116.008.1085002.06EPA 2458431 →
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21032660816.008.0082002.06EPA 2458895 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.