256 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8256 / 256
EER2 · BTU/Wh12.2–14256 / 256
HSPF2 · BTU/Wh7.8–8.5256 / 256
Cooling capacity · BTU/h18,000256 / 256
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000256 / 256
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100256 / 256
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700256 / 256
COP at 5°F / −15°C1.9–2.16256 / 256
Equipment / loop typeHP - Split System256 / 256
Refrigerant / source-reported GWPR-410A (GWP:2088)256 / 256
Compressor stagingSingle stage256 / 256
Connected capabilityNo256 / 256

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21471117316.407.8079001.96EPA 3485433
7EC30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21471116716.407.8081001.96EPA 3485434
7EC30BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 21471117416.407.8076001.98EPA 3485435
7EC24BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21471113516.408.1084002.08EPA 3485442
7EC24BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21471113616.408.0082002.10EPA 3485444
7EC30BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21471117716.407.8077001.98EPA 3485445
7EH24BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21471106116.408.1082002.06EPA 3485462
7EH24BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21471106216.408.1082002.08EPA 3485463
7EH24BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21471106516.408.1082002.08EPA 3485466
7EH24BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21471106616.408.1084002.06EPA 3485467
7EH30BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21471109916.407.8077001.98EPA 3485468
7EH30BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21471110016.407.8077002.00EPA 3485469
7EH30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21471110116.408.0080002.00EPA 3485470
7EC30AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21471115516.407.8077001.98EPA 3485490
7EC30AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21471115616.407.8077001.98EPA 3485491
7EC30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21471116016.407.8077001.98EPA 3485494
7EC30BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21471116116.407.8077002.00EPA 3485495
7EH24BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21471107516.408.1082002.10EPA 3485530
7EH30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21471108216.407.8077002.00EPA 3485537
7EC24AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21471112316.408.0082002.10EPA 3485558