Concord / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 3

256 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8256 / 256
EER2 · BTU/Wh12.2–14256 / 256
HSPF2 · BTU/Wh7.8–8.5256 / 256
Cooling capacity · BTU/h18,000256 / 256
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000256 / 256
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100256 / 256
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700256 / 256
COP at 5°F / −15°C1.9–2.16256 / 256
Equipment / loop typeHP - Split System256 / 256
Refrigerant / source-reported GWPR-410A (GWP:2088)256 / 256
Compressor stagingSingle stage256 / 256
Connected capabilityNo256 / 256

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7ED30/36BX-0*+TDR+ furnace: 92G1DF070BE12AHRI reference: 21471110816.608.5089002.10EPA 3485681
7EC30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21471115716.608.0080001.98EPA 3491837
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032662916.407.8077001.98EPA 2455642
EAC4X30B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032675516.407.8077002.00EPA 2455862
EAC4X30B+TDR+ furnace: 92G1UH045BE12AHRI reference: 21032674716.407.8076001.98EPA 2455940
EA(C;U)1P30B+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21032664216.407.8077002.00EPA 2457630
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 21032660116.408.1082002.12EPA 2457642
EAC4X24B+TDR+ furnace: 80G1UH070BE12AHRI reference: 21032671716.408.0082002.10EPA 2457650
EAC4X30B+TDR+ furnace: 80G2UH090BV16AHRI reference: 21032675816.408.0080001.96EPA 2457877
EAC4X24A+TDR+ furnace: 80G2UH070AE12AHRI reference: 21032671316.408.1082002.12EPA 2458109
EAC4X30B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032674316.407.8077001.98EPA 2458121
EAC4X24B+TDR+ furnace: 80G2UH090BE12AHRI reference: 21032672416.408.1081002.12EPA 2458151
EAC4X24A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21032670916.408.0082002.10EPA 2458398
EA(C;U)1P30B+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21032664516.408.0080001.96EPA 2458405
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032663016.407.8077001.98EPA 2458409
EA(C;U)1P30B+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21032663116.407.8077001.98EPA 2458423
EAC4X30B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032674416.407.8077001.98EPA 2458435
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032661916.407.8077001.98EPA 2459512
EAC4X24A+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21032671416.408.1082002.12EPA 2459726
EAC4X30A+TDR+ furnace: 80G1UH070AE12AHRI reference: 21032673216.407.8077001.98EPA 2459735