SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8256 / 256
EER2 · BTU/Wh12.2–14256 / 256
HSPF2 · BTU/Wh7.8–8.5256 / 256
Cooling capacity · BTU/h18,000256 / 256
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000256 / 256
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100256 / 256
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700256 / 256
COP at 5°F / −15°C1.9–2.16256 / 256
Equipment / loop typeHP - Split System256 / 256
Refrigerant / source-reported GWPR-410A (GWP:2088)256 / 256
Compressor stagingSingle stage256 / 256
Connected capabilityNo256 / 256

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAD4X-30/36C+TDR+ furnace: 96G1DF090CE16AHRI reference: 21326510816.008.4093002.06EPA 2839615
EAD4X-30/36B+TDR+ furnace: 80G1DF070BE12AHRI reference: 21326510116.008.3087002.06EPA 2839826
7ED30/36CX-0*+TDR+ furnace: 96G1DF090CE16AHRI reference: 21471111516.008.4093002.06EPA 3485169
7EC24AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471111816.008.1084002.06EPA 3485177
7EH30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21471109816.007.8078001.98EPA 3485207
7EH24AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471105116.008.1082002.02EPA 3485374
7EH24AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21471105816.008.1087002.04EPA 3485391
7EH24AX-0*+TDR+ furnace: 80G1UH040AE12XAHRI reference: 21471104916.007.8081002.00EPA 3485414
7EH24AX-0*+TDR+ furnace: 80G1UH060AE12XAHRI reference: 21471105016.007.8081002.00EPA 3485415
7EC24BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21471113316.008.1084002.06EPA 3485440
7EC24BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21471113416.008.0083002.12EPA 3485441
7EC30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21471117616.007.8078001.96EPA 3485443
7EH24BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21471106016.008.1082002.06EPA 3485461
7ED30/36BX-0*+TDR+ furnace: 97G2DF045BE12AHRI reference: 21471110316.008.3089002.08EPA 3485473
7ED30/36BX-0*+TDR+ furnace: 97G2DF070BE16AHRI reference: 21471110416.008.3089002.08EPA 3485475
7ED30/36BX-0*+TDR+ furnace: 80G1DF070BE12AHRI reference: 21471110616.008.3087002.06EPA 3485479
7EC30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21471115016.007.8079001.98EPA 3485505
7EH24BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21471107716.008.1082002.06EPA 3485533
7EH24BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21471107816.008.1082002.06EPA 3485535
7EH24BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21471107916.008.1087002.08EPA 3485536

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →