Comfortmaker / AIR-SOURCE HEAT PUMP

R5H5S19*K*AAA*

15 SEER2 HP · source records, page 3

77 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,700–19,300BTU/h

Each efficiency range summarizes published EPA records for R5H5S19*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 77 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–1677 / 77
EER2 · BTU/Wh12.5–1377 / 77
HSPF2 · BTU/Wh7.8–877 / 77
Cooling capacity · BTU/h17,700–19,30077 / 77
Heating capacity at 47°F / 8.3°C · BTU/h18,400–19,50077 / 77
Heating capacity at 17°F / −8.3°C · BTU/h10,300–11,00077 / 77
Heating capacity at 5°F / −15°C · BTU/h7,900–8,50077 / 77
COP at 5°F / −15°C1.9–277 / 77
Equipment / loop typeHP - Split System77 / 77
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)77 / 77
Compressor stagingSingle stage77 / 77
Connected capabilityNo77 / 77

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X19M17A*+ furnace: *97CMN0601714B*AHRI reference: 21770236515.508.0084002.00EPA 4507486 →
EA*5X25M17A*+ furnace: *96MSN0601412A*AHRI reference: 21770561315.508.0084002.00EPA 4507513 →
EA*5X19M17A*+ furnace: *97CMN0801714B*AHRI reference: 21770238715.508.0083002.00EPA 4507598 →
EA*5X25M17A*+ furnace: *96VSN0601716B*AHRI reference: 21770572015.508.0084002.00EPA 4507620 →
EA*5X25M17A*+ furnace: *95MSU0401712A*AHRI reference: 21770574315.507.8084001.90EPA 4507643 →
EA*5X19M17A*+ furnace: *96VTN0801716B*AHRI reference: 21770304515.508.0083002.00EPA 4507670 →
EA*5X19M17A*+ furnace: *97VTN0601716A*AHRI reference: 21770306815.508.0084002.00EPA 4507694 →
EA*5X19M17A*+ furnace: *97VTN0801716A*AHRI reference: 21770309115.508.0083002.00EPA 4507716 →
EA*5X19M17A*+ furnace: *92MSN0601412A*AHRI reference: 21770246015.508.0083002.00EPA 4507757 →
EA*5X25M17A*+ furnace: *96CTN0601714B*AHRI reference: 21770581615.508.0084002.00EPA 4507779 →
EA*5X25M17A*+ furnace: *80MS(N,L)0451714A*AHRI reference: 21770495115.508.0084002.00EPA 4507905 →
EA*5X25M17A*+ furnace: *97CTN0601716A*AHRI reference: 21770586015.508.0084002.00EPA 4508070 →
EA*5X25M17A*+ furnace: *97CTN0801716A*AHRI reference: 21770588215.508.0084002.00EPA 4508092 →
EA*5X25M17A*+ furnace: *96VTN0601412B*AHRI reference: 21770595715.508.0084002.00EPA 4508153 →
EA*5X25M17A*+ furnace: *96VTN0601716B*AHRI reference: 21770598215.508.0084002.00EPA 4508178 →
EA*5X25M17A*+ furnace: *97VTN0601716A*AHRI reference: 21770600715.508.0084002.00EPA 4508275 →
EA*5X25M17A*+ furnace: OMV098J12*AHRI reference: 21770605115.508.0083002.00EPA 4508297 →
EA*5X19M17A*+ furnace: *96MSN0601412A*AHRI reference: 21770261015.508.0084001.98EPA 4508311 →
EA*5X19M17A*+ furnace: *96MSN0801716A*AHRI reference: 21770266215.508.0084002.00EPA 4508334 →
EA*5X19M17A*+ furnace: *96VSN0601716B*AHRI reference: 21770274415.508.0084002.00EPA 4508356 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →