Q5H9V48*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 15
507 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 507 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 507 / 507 |
| EER2 · BTU/Wh | 10–13.5 | 507 / 507 |
| HSPF2 · BTU/Wh | 8.5–10 | 507 / 507 |
| Cooling capacity · BTU/h | 43,500–49,500 | 507 / 507 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,500–55,000 | 507 / 507 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 38,500–47,000 | 507 / 507 |
| Heating capacity at 5°F / −15°C · BTU/h | 36,000–41,500 | 507 / 507 |
| COP at 5°F / −15°C | 1.95–2.32 | 507 / 507 |
| Equipment / loop type | HP - Split System | 507 / 507 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 507 / 507 |
| Compressor staging | Continuously variable | 507 / 507 |
| Connected capability | No | 507 / 507 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X60M24A*+ furnace: *96VTN1202422B*Cold climate designationAHRI reference: 217929361 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4545799 → |
ESH5X60M12A*+ furnace: *96VSN1202422B*Cold climate designationAHRI reference: 217931145 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4545922 → |
EA*5X60M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217929335 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4545954 → |
EA*5X61M24A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217930155 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4546093 → |
EA*5X61M24A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 217930181 | 16.00 | 9.00 | 37400 | 2.08 | EPA 4546217 → |
EA*5X61M24A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 217930194 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4546229 → |
EA*5X61M24A*+ furnace: *97VTN1002120A*Cold climate designationAHRI reference: 217930285 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4546264 → |
EA*5X61M24A*+ furnace: *97VTN1002122A*Cold climate designationAHRI reference: 217930298 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4546277 → |
EA*5X61M24A*+ furnace: *97VTN1202422A*Cold climate designationAHRI reference: 217930311 | 16.00 | 9.00 | 37600 | 2.08 | EPA 4546290 → |
ESH5X60M12A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 217931223 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4546329 → |
EA*5X48M21A*+ furnace: *97VTN0802120A*Cold climate designationAHRI reference: 217928983 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4546587 → |
EA*5X61M24A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 217929907 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4546715 → |
EA*5X61M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 217929686 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4546786 → |
ESH5X60M12A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 217930897 | 16.00 | 9.00 | 36600 | 2.10 | EPA 4546861 → |
EA*5X61M21A*+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 217929660 | 16.00 | 9.00 | 37200 | 2.08 | EPA 4546894 → |
EA*5X61M24A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 217930011 | 16.00 | 9.00 | 37200 | 2.10 | EPA 4546961 → |
EA*5X61M24A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 217930024 | 16.00 | 9.00 | 37000 | 2.10 | EPA 4546974 → |
EA*5X48M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 217928931 | 16.00 | 9.00 | 36800 | 2.08 | EPA 4547051 → |
ESH5X48M12A*+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 217930480 | 16.00 | 8.50 | 36600 | 2.00 | EPA 4547100 → |
EA*5X61M24A*+ furnace: *96VTN1002120B*Cold climate designationAHRI reference: 217930233 | 16.00 | 9.00 | 37400 | 2.10 | EPA 4547119 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →