Comfortmaker / AIR-SOURCE HEAT PUMP

Q5H9V36*K*AAA*

QuietComfort 19 SEER2 VS HP · source records, page 22

450 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–9BTU/Wh
Cooling capacity33,400–37,600BTU/h

Each efficiency range summarizes published EPA records for Q5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18450 / 450
EER2 · BTU/Wh10.5–13.5450 / 450
HSPF2 · BTU/Wh7.8–9450 / 450
Cooling capacity · BTU/h33,400–37,600450 / 450
Heating capacity at 47°F / 8.3°C · BTU/h31,800–37,400450 / 450
Heating capacity at 17°F / −8.3°C · BTU/h25,200–37,600450 / 450
Heating capacity at 5°F / −15°C · BTU/h24,600–26,600450 / 450
COP at 5°F / −15°C1.9–2.18450 / 450
Equipment / loop typeHP - Split System450 / 450
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)450 / 450
Compressor stagingContinuously variable450 / 450
Connected capabilityNo450 / 450

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X43M21A*+ furnace: *80MSU1002120A*AHRI reference: 21792473615.209.00246002.08EPA 4539609 →
EA*5X42M21A*+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21792436115.209.00256002.08EPA 4539980 →
EA*5X42M21A*+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21792437615.209.00254002.10EPA 4539987 →
EA*5X42M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 21792446615.209.00256002.08EPA 4539991 →
EA*5X37M21A*+ furnace: *80CSU1002120B*AHRI reference: 21792305415.209.00248002.08EPA 4540214 →
EA*5X36M17A*+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 21792248215.208.50256001.98EPA 4540379 →
EA*5X43M21A*+ furnace: *96VTN0801716B*AHRI reference: 21792526215.209.00250002.06EPA 4540566 →
EA*5X42M21A*+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21792440615.209.00256002.08EPA 4540717 →
EA*5X42M21A*+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21792442115.209.00254002.10EPA 4540730 →
EA*5X43M21A*+ furnace: *80VTL1102122B*AHRI reference: 21792487215.208.50248001.94EPA 4541274 →
EA*5X43M21A*+ furnace: *97CMN0801714B*AHRI reference: 21792496215.209.00250002.06EPA 4541294 →
EA*5X48M21A*+ furnace: *80CTL0701716B*AHRI reference: 21792560715.209.00254002.06EPA 4541397 →
EA*5X48M21A*+ furnace: *80CTL0702120B*AHRI reference: 21792562215.209.00252002.06EPA 4541412 →
EA*5X37M17A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 21792276915.209.00256002.08EPA 4541478 →
EA*5X36M17A*+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 21792228515.208.50252002.00EPA 4541555 →
EA*5X36M17A*+ furnace: *80VTL0451412B*Cold climate designationAHRI reference: 21792230015.208.50252002.00EPA 4541574 →
EA*5X36M17A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 21792231615.208.50252002.00EPA 4541588 →
EA*5X43M21A*+ furnace: *95CSU0802120B*AHRI reference: 21792490215.209.00248002.08EPA 4541614 →
EA*5X48M21A*+ furnace: *95CSU0802120B*AHRI reference: 21792574315.209.00252002.06EPA 4541632 →
EA*5X43M21A*+ furnace: *96VSN0801716B*AHRI reference: 21792502215.209.00250002.06EPA 4541879 →