Q5H9V36*K*AAA*
QuietComfort 19 SEER2 VS HP · source records, page 13
450 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for Q5H9V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 450 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 450 / 450 |
| EER2 · BTU/Wh | 10.5–13.5 | 450 / 450 |
| HSPF2 · BTU/Wh | 7.8–9 | 450 / 450 |
| Cooling capacity · BTU/h | 33,400–37,600 | 450 / 450 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,800–37,400 | 450 / 450 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,200–37,600 | 450 / 450 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–26,600 | 450 / 450 |
| COP at 5°F / −15°C | 1.9–2.18 | 450 / 450 |
| Equipment / loop type | HP - Split System | 450 / 450 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 450 / 450 |
| Compressor staging | Continuously variable | 450 / 450 |
| Connected capability | No | 450 / 450 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X37M21A*+ furnace: *97CMN0802120B*AHRI reference: 217923415 | 15.50 | 9.00 | 24800 | 2.08 | EPA 4541775 → |
EA*5X37M21A*+ furnace: *97CMN1002122B*AHRI reference: 217923430 | 15.50 | 9.00 | 24800 | 2.06 | EPA 4541790 → |
EA*5X48M21A*+ furnace: *80CSU0401712B*AHRI reference: 217925412 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4541793 → |
EA*5X48M21A*+ furnace: *80CSU0601716B*AHRI reference: 217925427 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4541812 → |
EA*5X48M21A*+ furnace: *80CSU1002120B*AHRI reference: 217925457 | 15.50 | 9.00 | 25200 | 2.08 | EPA 4541844 → |
EA*5X43M21A*+ furnace: *96VSN1002120B*AHRI reference: 217925052 | 15.50 | 9.00 | 24800 | 2.08 | EPA 4541891 → |
EA*5X42M21A*+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 217923850 | 15.50 | 8.50 | 25400 | 2.00 | EPA 4541905 → |
EA*5X42M21A*+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 217923880 | 15.50 | 9.00 | 25400 | 2.10 | EPA 4541933 → |
EA*5X48M21A*+ furnace: *97CMN0802120B*AHRI reference: 217925818 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4542269 → |
EA*5X48M21A*+ furnace: *97CMN1002122B*AHRI reference: 217925833 | 15.50 | 9.00 | 25200 | 2.08 | EPA 4542285 → |
EA*5X48M21A*+ furnace: *96VTN1002120B*AHRI reference: 217926148 | 15.50 | 9.00 | 25200 | 2.08 | EPA 4542685 → |
EA*5X48M21A*+ furnace: *97VTN1002120A*AHRI reference: 217926223 | 15.50 | 9.00 | 25200 | 2.08 | EPA 4543083 → |
EA*5X48M21A*+ furnace: *96VSN1002120B*AHRI reference: 217925893 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4543210 → |
EA*5X48M21A*+ furnace: *95MSU1002120A*AHRI reference: 217925953 | 15.50 | 9.00 | 25200 | 2.08 | EPA 4543926 → |
EA*5X48M21A*+ furnace: *95MSU1002122A*AHRI reference: 217925968 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4543948 → |
EA*5X48M21A*+ furnace: *96CTN0802120B*AHRI reference: 217926013 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4544260 → |
EA*5X48M21A*+ furnace: *96CTN1002122B*AHRI reference: 217926028 | 15.50 | 9.00 | 25200 | 2.08 | EPA 4544274 → |
EA*5X48M21A*+ furnace: *97CTN0802120A*AHRI reference: 217926073 | 15.50 | 9.00 | 25200 | 2.06 | EPA 4544738 → |
EA*5X48M21A*+ furnace: *97CTN1002122A*AHRI reference: 217926088 | 15.50 | 9.00 | 25200 | 2.08 | EPA 4544752 → |
EA*5X36M17A*+ furnace: OMV112K14ACold climate designationAHRI reference: 217952515 | 15.50 | 8.50 | 25800 | 1.96 | EPA 4560081 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →